2024年5月25日发(作者:)

storcli64查看raid

[root@localhost ~]# ./storcli64 show ctrlcount ---查看raid数量

Status Code = 0

Status = Success

Description = None

Controller Count = 1

[root@localhost ~]#

[root@localhost ~]# ./storcli64 /c0 /v0 show ---查看raid结构,虚拟硬盘

Controller = 0

Status = Success

Description = None

Virtual Drives :

==============

---------------------------------------------------------------

DG/VD TYPE State Access Consist Cache Cac sCC Size Name

---------------------------------------------------------------

0/0 RAID0 Optl RW Yes RWTD - ON 446.625 GB

---------------------------------------------------------------

Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded

Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|

Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|

AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled

Check Consistency

[root@localhost ~]#

[root@localhost ~]# ./storcli64 /c0 /eall /sall show ---查看物理硬盘

Controller = 0

Status = Success

Description = Show Drive Information Succeeded.

Drive Information :

=================

----------------------------------------------------------------------------

EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp

----------------------------------------------------------------------------

8:0 11 JBOD - 3.637 TB SATA HDD N N 512B ST4000NM000A-2HZ100 U

8:1 9 JBOD - 3.637 TB SATA HDD N N 512B ST4000NM000A-2HZ100 U

8:12 21 JBOD - 446.625 GB SATA SSD N N 512B Maxtor Z1 SSD 480GB U

8:13 22 Onln 0 446.625 GB SATA SSD N N 512B Maxtor Z1 SSD 480GB U

----------------------------------------------------------------------------

EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup

DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare

UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface

Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info

SeSz-Sector Size|Sp-Spun|U-Up|D-Down/PowerSave|T-Transition|F-Foreign

UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded

CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded

[root@localhost ~]# lsblk

NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINT

sda 8:0 0 3.7T 0 disk

├─sda1 8:1 0 200M 0 part

├─sda2 8:2 0 1G 0 part

└─sda3 8:3 0 445.4G 0 part

├─klas-swap 252:2 0 4G 0 lvm

└─klas-root 252:3 0 441.4G 0 lvm

sdb 8:16 0 3.7T 0 disk

├─sdb1 8:17 0 1.9T 0 part

├─sdb2 8:18 0 1.3T 0 part

└─sdb4 8:20 0 1.6T 0 part

sdc 8:32 0 447.1G 0 disk

sdd 8:48 0 446.6G 0 disk

├─sdd1 8:49 0 200M 0 part /boot/efi

├─sdd2 8:50 0 1G 0 part /boot

└─sdd3 8:51 0 445.4G 0 part

├─klas00-root 252:0 0 441.4G 0 lvm /

└─klas00-swap 252:1 0 4G 0 lvm [SWAP]

sr0 11:0 1 1024M 0 rom

sr1 11:1 1 1024M 0 rom

sr2 11:2 1 1024M 0 rom

sr3 11:3 1 1024M 0 rom

[root@localhost ~]#

[root@localhost ~]# ./storcli64 show all

Segmentation fault (core dumped)

[root@localhost ~]# ./storcli64 /c0 show all

Generating detailed summary of the adapter, it may take a while to complete.

Controller = 0

Status = Failure

Description = None

Detailed Status :

===============

------------------------------------------------

Ctrl Status ErrCd ErrMsg

------------------------------------------------

0 Failed 255 Failed to get Bus Information

------------------------------------------------

Basics :

======

Controller = 0

Model = AVAGO MegaRAID SAS 9361-8i 2GB

Serial Number = SK84171618

Current Controller Date/Time = 09/05/2019, 09:28:34

Current System Date/time = 09/05/2019, 17:28:34

SAS Address = 500605b00ece47f0

PCI Address = NA

Mfg Date = 10/12/18

Rework Date = 00/00/00

Revision No = 22002

Version :

=======

Firmware Package Build = 24.21.0-0017

Firmware Version = 4.680.00-8274

CPLD Version = 26747-01A

Bios Version = 6.36.00.1_4.19.08.00_0x06180202

HII Version = 03.25.05.03

Ctrl-R Version = 5.19-0601

Preboot CLI Version = 01.07-05:#%0000

NVDATA Version = 3.1705.00-0005

Boot Block Version = 3.07.00.00-0003

Driver Name = megaraid_sas

Driver Version = 07.706.03.00-rc1

Bus :

===

Vendor Id = 0x1000

Device Id = 0x5D

SubVendor Id = 0x1000

SubDevice Id = 0x9361

Host Interface = PCI-E

Device Interface = SAS-12G

Pending Images in Flash :