2023年12月3日发(作者:)

LCD Messages

The following table provides detail on error messaged that may be

displayed on the system LCD.

NOTE:

If the user presses and holds the ID button for approximately 5

seconds, the LCD will enter the BIOS Progress Code state. This feature

is very useful when troubleshooting a no POST or no video situations.

Cable and Board Presence -

Message Code: x1Axx

Voltages - Message Code:

x12xx

Processors - Message Code:

x14xx

Power Supplies - Message

Code: x16xx

Hard Drives - Message Code:

x18xx

BIOS Progress Codes - Message

Code: N/A

Temperature - Message Code:

x11xx

Fans - Message Code: x13xx

System Memory - Message Code:

x21xx

BIOS - Message Code: x17xx

Miscellaneous - Message Code:

x19xx

BIOS Fatal Error Codes -

Message Code: x20xx

Special Exceptions - Message

Code: x10xx

Cable and Board Presence -

Message Code: "x1Axx"

System

MessaExisPhase

MessMinimum Action

Message ge ts When

age Message Comments Required to Remove

String Priorin Event

Code Message from LCD

ity SEL? Can

Occur

PDB power cable to

the planar is Failing device is

E1A1PDBPwrCablPre-PHigh missing or bad and reseated/replaced/Yes

0 e ost

system will not repaired.

power on.

PCI risers are not

configured

Failing device is

E1A1PCIRsrConfcorrectly; some Pre-PHigh reseated/replaced/Yes

1 ig invalid ost

repaired.

configurations

prevent system power on.

One or all of the

PCI risers is Failing device is

E1A1PCIRsrMissPre-PHigh missing. This reseated/replaced/Yes

2 ing ost

prevents system repaired.

power on.

E1A1SAS cable A is

SAS Cable A Low

4 missing or bad.

E1A1SAS cable B is

SAS Cable B Low

5 missing or bad.

Failing device is

reseated/replaced/Yes Any

repaired.

Failing device is

reseated/replaced/Yes Any

repaired.

Failing device is

E1A1SAS Cable Flex bay SAS cable

Low reseated/replaced/Yes Any

6 FB is missing or bad.

repaired.

Flex bay power Failing device is

E1A1PwrCable

Low cable is missing or reseated/replaced/Yes Any

7 FB

bad. repaired.

PDB control cable

to the planar is Failing device is

High missing or bad and reseated/replaced/Yes Any

system will not repaired.

power on.

Temperature -

Message Code: "x11xx"

System

MessaExisPhase

MessMinimum Action

Message ge ts When

age Message Comments Required to Remove

String Priorin Event

Code Message from LCD

ity SEL? Can

Occur

Ambient

temperature has a Temperature

Med reached a point returns to Yes Any

outside of the allowable range.

allowed range.

Memory has exceeded

allowable

AC Cycle or SEL

High temperature and has

clear

been disabled to

prevent damage to

E1A1PDBCtrl

8 Cable

E111Temp

4 Ambient

E111Temp

6 Memory

Yes Any the components.

Voltages -

Message Code: "x12xx"

System

MessaExisPhase

MessMinimum Action

Message ge ts When

age Message Comments Required to Remove

String Priorin Event

Code Message from LCD

ity SEL? Can

Occur

CMOS battery is

missing or the Failing device is

E121CMOSBatt Low voltage is outside reseated/replaced/Yes Any

0

of the allowable repaired.

range.

PERC5I RAID battery

charger has

reported to the

Server Management

that the battery is Failing device is

E121ROMBBatt Low either missing, reseated/replaced/Yes Any

1

can't charge the repaired.

battery (possibly

because of high

temperatures), or

the battery is bad.

This is a

predictive failure

warning message

telling the user

that the PERC5I

Battery charges

W122ROMBBatt< RAID battery has

Low to > 24 hours of Yes Any

8 24 hr less then 24 hours

sustained charge.

of charge left

init. Wee provide

this message as a

warning message to

the customer.

1.5 VV voltage

E1211.5VPwrGd High regulator has

4

failed.

E1211.8 VV voltage

1.8VPwrGd High

5 regulator has

AC Cycle or SEL

clear

AC Cycle or SEL

clear

Yes Any

Yes Any failed.

3.3V voltage

E1213.3VPwrGd High regulator has

6

failed.

E1215VPwrGd

7

5V voltage

High regulator has

failed.

AC Cycle or SEL

clear

AC Cycle or SEL

clear

Yes Any

Yes Any

PCI Riser 5V

E121PCIRsr5VPwAC Cycle or SEL

High voltage regulator

8 rGd clear

has failed.

Backplane voltage

E121BackplanePAC Cycle or SEL

High regulator has

9 wrGd clear

failed.

Flex Bay voltage

E122Flex AC Cycle or SEL

High regulator power

1 BayPwrGd clear

good has failed.

E122VCACHE

2 #PwrGd

VCACHE # voltage

AC Cycle or SEL

High regulator has

clear

failed.

AC Cycle or SEL

clear

Yes Any

Yes Any

Yes Any

Yes Any

VRM # voltage

E122VRM #PwrGd High regulator has

3

failed.

Yes Any

ESB1.5 VV voltage

E122ESB AC Cycle or SEL

High regulator has

5 1.5VPwrGd clear

failed.

PCI Riser 1.5 VV

E122PCIRsr1.5VAC Cycle or SEL

High voltage regulator

6 PwrGd clear

has failed.

Linear voltage

regulator(s) has

failed. Represents

E122LinearPwrGAC Cycle or SEL

High status of multiple

7 d clear

voltage regulators

used in the video

and LOM circuitry.

Memory VTT voltage

E122AC Cycle or SEL

0.9VPwrGd High regulator has

8 clear

failed.

Processor # VCORE

E122AC Cycle or SEL

CPU # VCORE High voltage regulator

9 clear

has failed.

Yes Any

Yes Any

Yes Any

Yes Any

Yes Any Processor VTT

E122CPU AC Cycle or SEL

High voltage regulator

A VTTPwrGd clear

has failed.

0.9 V regulator

voltage has

E1220.9 V Over AC Cycle or SEL

High exceeded the

B Voltage clear

allowable voltage

range.

A voltage regulator

failure was

E122CPU Power detected when the AC Cycle or SEL

High

C Fault processor clear

regulator(s) was

enabled.

Fans -

Message Code: "x13xx"

Yes Any

Yes Any

Yes Any

MessaMessMessage ge

age

String PriorCode

ity

E131RPM Fan ## Low

0

E131RPM Fan Mod

Low

1 #A

E131RPM Fan Mod

Low

1 #B

System

ExisPhase

Minimum Action

ts When

Message Comments Required to Remove

in Event

Message from LCD

SEL? Can

Occur

Fan RPM reading

RPM of fan ## is

returns to a point

outside of the

inside of the Yes Any

intended operating

intended operating

range.

range.

Fan RPM reading

RPM of fan A in the

returns to a point

# module is outside

inside of the Yes Any

of the intended

intended operating

operating range.

range.

Fan RPM reading

Same as above returns to a point

except for fan B of inside of the Yes Any

module #. intended operating

range.

Fan RPM reading

Same as above

E131RPM Fan Mod returns to a point

Low except for fan C of Yes Any

1 #C inside of the

module #.

intended operating range.

Fan RPM reading

Same as above returns to a point

E131RPM Fan Mod

Low except for fan D of inside of the Yes Any

1 #D

module #. intended operating

range.

The system is no

Fan redundancy is

longer fan

regained, which

redundant. Another

E131Fan requires all fans

Low fan failure would Yes Any

3 Redundancy to be operating

put the system at

within the intended

risk of

operating range.

over-heating.

Processors -

Message Code: "x14xx"

System

MessaExisPhase

MessMinimum Action

Message ge ts When

age Message Comments Required to Remove

String Priorin Event

Code Message from LCD

ity SEL? Can

Occur

Processor # has had

an internal error

(IERR), but this

doesn’t always

E141AC Cycle or SEL

CPU # IERR High mean that CPU is the

0 clear

problem .There are

a large variety of

issues that cause

an IERR.

Processor # has

E141CPU encountered a AC Cycle or SEL

High

4 #Thermtrip Thermtrip(over-temclear

perature) event.

Processor # is

missing/bad and the

E141CPU # AC Cycle or SEL

High system is in an

8 Presence clear

unsupported

configuration.

E141CPU Processors are not AC Cycle or SEL

High

C Mismatch compatible as clear

Yes Any

Yes Any

Pre-PYes

OST

Yes

Pre-POST defined by

Dell .System is in

an unsupported

configuration.

BIOS has reported a

E141CPU AC Cycle or SEL

High processor protocol

F Protocol clear

error.

E142CPU Bus

0 PERR

BIOS has reported a

AC Cycle or SEL

High processor bus PERR

clear

(parity error).

POST,

Yes After

POST

POST,

Yes After

POST

POST,

Yes After

POST

POST,

Yes After

POST

BIOS has reported a

E142processor AC Cycle or SEL

CPU Init High

1 initialization clear

error.

BIOS has reported a

E142CPU AC Cycle or SEL

High machine check

2 MachineChk clear

error.

System Memory -

Message Code: "x21xx"

System

MessaExisPhase

MessMinimum Action

Message ge ts When

age Message Comments Required to Remove

String Priorin Event

Code Message from LCD

ity SEL? Can

Occur

One of the DIMMM's

in the set

implicated by "## &

##" has had a

multi-bit error

MBECrdx

E211(MBE).If no memory AC Cycle or SEL

DIMM ## & High

0 riser is present clear

##

the “Crdx” string

is left out of the

message.“x” is

the memory riser,

A-Z.

BIOS has disabled

SBE Log

E211memory single-bit

DisableCrdHigh System reset

1 error (SBE) logging

x DIMM ##

and will not log

POST,

Yes After

POST

POST,

Yes After

POST anymore SBEE's

until the system is

rebooted.##

represents DIMM

implicated by

BIOS .If no memory

riser is present

the “Crd x”

string is left out

of the

message.“x” is

the memory riser,

A-Z.

BIOS has spared the

memory because it

has determined the

memory had too many

errors.##

represents DIMM

E211MemSpareCrimplicated by BIOS.

High System reset

2 dx DIMM ## If no memory riser

is present the

“Crdx” string is

left out of the

message.“x” is

the memory riser,

A-Z.

BIOS has disabled

memory mirroring

because it has

determined one half

of the mirror has

had too many

errors. ## & ##

Mem Mirror

E211represents DIMM

Crd x DIMM High System reset

3 pair implicated by

## & ##

BIOS. If no memory

riser is present

the “Crdx” string

is left out of the

message.“x” is

the memory riser,

A-Z.

POST,

Yes After

POST

POST,

Yes After

POST I211MemRaid

4

Low

BIOS Memory RAID User action, sensor

Yes Any

Bank return to normal

Yes Any

Memory has been

I211MemAdded AC Cycle or SEL

Low added while the

5 Card x clear

system is running.

Memory has been

I211AC Cycle or SEL

MemRemoved Low removed while the

6 clear

system is running.

E211MemHot

7 Plug

Memory hot-plug

Low operation has

failed.

AC Cycle or SEL

clear

Yes Any

Yes Any

Northbound FBD CRC

error on

non-redundant

entry. One of the

connections in the

FBD link on the

Northbound

E211Fatal AC Cycle or SEL

High (towards the MCH)

8 NBMemCRC clear

side is

"broken".This is

determined by the

MCH when two CRC

errors have been

detected twice in a

row.

FBD alert on

non-redundant

entry. One of the

connections in the

FBD link on the

Southbound

(towards the

E211Fatal AC Cycle or SEL

High AMB'son the

9 SBMemCRC clear

FBDIMM's) side is

"broken".This is

determined by the

MCH when two CRC

errors have been

detected twice in a

row.

Power Supplies -

Message Code: "x16xx"

MessMessage MessaMessage Comments

POST,

Yes After

POST

POST,

Yes After

POST

Minimum Action ExisSysteage String ge

Code Priority

Required to Remove ts m

Message from LCD in Phase

SEL? When

Event

Can

Occur

E161PS #

0 Missing

Power supply # was

Failing device is

removed or is

Low reseated/replaced/Yes Any

missing from the

repaired.

system.

Failing device is

E161Power supply # has

PS # Status Low reseated/replaced/Yes Any

4 failed.

repaired.

Power supply # has a

failure that

predicts a power

Failing device is

E161PS # down event in this

Low reseated/replaced/Yes Any

8 Predictive supply (i.e. power

repaired.

supply fan failure

or power supply

over-temp).

Power supply # is

Failing device is

E161PS # Input attached to the

Low reseated/replaced/Yes Any

C Lost system but has lost

repaired.

its AC/DC input.

Power supply #'s

Failing device is

E162PS #Input AC/DC input is

Low reseated/replaced/Yes Any

0 Range outside of the

repaired.

allowable range.

The power supply

subsystem is no

Failing device is

E162PS longer redundant.

Low reseated/replaced/Yes Any

4 Redundancy If the last supply

repaired.

fails the system

will go down.

The power supply

input power is Failing device is

Low above the allowed reseated/replaced/Yes Any

amount for the repaired.

power supply.

BIOS -

Message Code: "x17xx"

E162PS AC

5 Current System

MessaExisPhase

MessMinimum Action

Message ge ts When

age Message Comments Required to Remove

String Priorin Event

Code Message from LCD

ity SEL? Can

Occur

BIOS has reported

E171I/O AC Cycle or SEL

High an I/O channel

0 ChannelChk clear

check.

BIOS has reported

PCI parity error on

a component that

E171PCI PERR resides in PCI AC Cycle or SEL

High

1 B## D## F## configuration clear

space at bus ##,

device ##, function

##.

BIOS has reported

E171PCI PERR PCI parity error on

High Same as above.

1 Slot # a component that

resides in slot #.

BIOS has reported a

PCI system error on

a component that

E171PCI SERR resides in PCI AC Cycle or SEL

High

2 B## D## F## configuration clear

space at bus ##,

device ##, function

##.

BIOS has reported a

E171PCI SERR PCI system error on

High Same as above.

2 Slot # a component that

resides in slot #.

BIOS has determined

there has been an

error in the system AC Cycle or SEL

Low

but is unable to clear

determine its

origin.

POST,

Yes After

POST

POST,

Yes After

POST

Same Same

as as

abovabovee. .

POST,

Yes After

POST

Same Same

as as

abovabovee. .

E171Unknown

4 Err

POST,

Yes After

POST

E171PCIE Fatal BIOS has reported a AC Cycle or SEL

High

F Err B## D## PCIe fatal error on clear

Yes

POST,

After F## a component that

resides in PCI

configuration

space at bus ##,

device ##, function

##.

POST

BIOS has reported a

E171PCIE Fatal PCIe fatal error on

High Same as above.

F Slot # a component that

resides in slot #.

Hard Drives -

Message Code: "x18xx"

Same Same

as as

abovabovee. .

System

MessaExisPhase

MessMinimum Action

Message ge ts When

age Message Comments Required to Remove

String Priorin Event

Code Message from LCD

ity SEL? Can

Occur

E181HDD ##

0 Fault

Hard drive ## has

had a fault as AC Cycle or SEL

Low

determined by the clear

SAS subsystem.

POST,

Yes After

POST

POST,

Yes After

POST

E181HDD Drive ## has had its AC Cycle or SEL

Low

1 ##RbldAbrt rebuild aborted. clear

E181HDD ##

2 Removed

System reset or

Drive ## has been POST,

device is

Low removed from the Yes After

reseated/replaced/system. POST

repaired.

Miscellaneous-

Message Code: "x19xx"

System

MessaExisPhase

MessMinimum Action

Message ge ts When

age Message Comments Required to Remove

String Priorin Event

Code Message from LCD

ity SEL? Can

Occur

Chassis lid is

I191The chassis lid has

Intrusion Low returned to the

0 been removed.

system.

Yes Any User must check the

system event log

(SEL) for the rest

of the errors on the

system .Thee LCD is

Less than 3 events

I191>3ERRsChkLlimited to three

N/A to display on the No Any

1 og error, warning,

LCD.

and/or

informational

messages at a time

based on priority

level.

System Event Log is

full of events and

because of this is

unable to log

I191anymore. You must AC Cycle or SEL

SEL Full Med

2 clear the log in clear

order for the

Server Management

controller to log

any more events.

Current version of

CPU & BMC firmware is

E191AC Cycle or SEL

Firmware Med incompatible with

3 clear

Mismatch the Woodcrest

processor.

BIOS Progress Codes -

Message Code: N/A

System

MessaExisPhase

MessMinimum Action

Message ge ts When

age Message Comments Required to Remove

String Priorin Event

Code Message from LCD

ity SEL? Can

Occur

N/A POWER

N/A MCODE

N/A CINIT

N/A

N/A

N/A

0x01 -- System

power-on.

0x02 -- CPU

Microcode load.

0x03 -- Chipset

Initialization.

N/A

N/A

N/A

No Any

No Any

No Any

Yes Any

Yes POST N/A MEMC

N/A SBIOS

N/A

N/A

0x04 -- Memory

Configuration.

N/A No Any

No Any

0x05 -- BIOS shadow

N/A

into memory.

N/A N/A PINIT

0x06 --

N/A Multiprocessor

Initialization.

N/A

No Any

N/A START

0x07 -- POST

N/A

processing start.

No Any

N/A SMM

0x08 -- System

management

N/A

interrupt (SMI)

initialization.

N/A No Any

N/A PCIEN

0x09 -- PCI Bus

N/A Enumeration & Video N/A

initialization.

N/A

N/A

N/A

0x40 -- Display

sign-on.

0x41 -- PCI

Configuration.

0x7F -- Give

control to OS.

N/A

N/A

N/A

No Any

N/A VIDEO

N/A PCIC

N/A OS

No Any

No Any

No Any

N/A E2010

0x80 -- No memory

N/A installed in the N/A

system.

0x81 -- Memory

detected but is not

configurable .Error detected during

memory

N/A N/A

configuration.

Could be result of

bad memory,

mismatched memory

or bad socket.

0x82 -- Memory

configured but not

usable. Memory

N/A sub-system N/A

failure. Could be

the result of bad

memory.

No Any

N/A E2011 No Any

N/A E2012 No Any N/A E2013

0x83 -- BIOS failed

to copy its flash

N/A image into memory. N/A

Could be the result

of bad memory.

0x84 -- CMOS

N/A failure. CMOS'S RAM N/A

not working.

0x05 -- DMA

N/A controller

failure.

N/A

No Any

N/A E2014 No Any

N/A E1215 No Any

N/A E1116

0x80 -- Interrupt

N/A controller N/A

failure.

N/A

0x07 -- Timer

N/A

refresh failure.

No Any

N/A E1217 No Any

N/A E1218

0x28 --

Programmable

N/A

interval timer

error.

N/A

N/A

0x29 -- Parity

error.

0x2a -- SIO

failure.

N/A No Any

N/A E0119

N/A E122A

N/A

N/A

No Any

No Any

N/A E122B

0x00b0 -- Keyboard

N/A controller N/A

failure.

0x3c -- System

management

N/A interrupt (SMI)

initialization

failure.

0xC4 -- BIOS

N/A shutdown test

failure.

No Any

N/A E141C N/A No Any

N/A E.11 N/A No Any

N/A E.11

0xC4 -- BIOS POST

memory test

N/A failure. Could be N/A

the result of bad

memory.

N/A

0xC4 -- Dell remote

N/A

access controller

No Any

N/A E141F No Any (DRAC)

configuration

failure. Check

screen for the

actual error

message.

0xC4 -- CPU

configuration

failure. Check

N/A

screen for the

actual error

message.

N/A E0000 N/A No Any

N/A E1221

0xC4 -- Incorrect

memory

configuration.

N/A Memory population N/A

order not correct.

Refer to the user

guide.

22x -- General

failure after

N/A video. Check screen N/A

for the actual

error message.

No Any

N/A E1222 No Any

BIOS Fatal Error Codes -

Message Code: "x20xx"

System

MessaExisPhase

MessMinimum Action

Message ge ts When

age Message Comments Required to Remove

String Priorin Event

Code Message from LCD

ity SEL? Can

Occur

0x80 -- No memory

E201No Memory High installed in the System reset

0

system.

0x81 -- Memory

detected but is not

configurable.

E201MemConfigEHigh Error detected System reset

1 rr

during memory

configuration.

Could be result of

Yes POST

Yes POST bad memory,

mismatched memory

or bad socket.

0x82 -- Memory

configured but not

usable. Memory

E201Unusable

High sub-system System reset

2 Memory

failure. Could be

the result of bad

memory.

0x83 -- BIOS failed

to copy its flash

E201Shadow

High image into memory. System reset

3 BIOS Fail

Could be the result

of bad memory.

0x84 -- CMOS

E201CMOS Fail High failure. CMOS'S RAM System reset

4

not working.

0x85 -- DMA

E201DMA

High controller

5 Controller

failure.

System reset

Yes POST

Yes POST

Yes POST

Yes POST

0x86 -- Interrupt

E201IntControlHigh controller System reset

6 ler

failure.

E2010x87 -- Timer

Timer Fail High System reset

7 refresh failure.

0x88 --

E201Programmable

ProgTimer High

8 interval timer

error.

E201Parity

9 Error

E201SIO Err

A

High

High

0x89 -- Parity

error.

0x8A -- SIO

failure.

Yes POST

Yes POST

System reset Yes POST

System reset

System reset

Yes POST

Yes POST

0x8B -- Keyboard

E201KybdControHigh controller System reset

B ller

failure.

0x8C -- System

management

E201SMI Init High interrupt (SMI)

C

initialization

failure.

Yes POST

System reset Yes POST 0xC0 -- BIOS

E201Shutdown

High shutdown test

D Test

failure.

System reset Yes POST

0xC1 -- BIOS POST

memory test

E201POSTMemTesHigh failure. Could be System reset

E t

the result of bad

memory.

0xC2 -- Dell remote

access controller

(DRAC)

E201configuration

DRACConfig High System reset

F failure. Check

screen for the

actual error

message.

0xC3 -- CPU

configuration

E202failure. Check

CPUConfig High

0 screen for the

actual error

message.

Yes POST

Yes POST

System reset Yes POST

0xC4 -- Incorrect

memory

configuration.

E202Memory

High Memory population System reset

1 Population

order not correct.

Refer to the user

guide.

0xFE -- General

failure after

E202POST Fail High video. Check screen System reset

2

for the actual

error message.

Special Exceptions -

Message Code: "x10xx"

Yes POST

Yes POST

System

MessaExisPhase

MessMinimum Action

Message ge ts When

age Message Comments Required to Remove

String Priorin Event

Code Message from LCD

ity SEL? Can

Occur Failsafe, Check System Event

E100SpeciAC Cycle or SEL

Call Log for critical

0 al clear

Support failure details.

Previous

Yes Any

Next