2023年12月29日发(作者:)
液压支架操作(Hydraulic support operation)
Two, operation procedures
Send the power to PM32, observe whether the PM32 display is
normal or not, if not normal, do it in time.
Observe whether the bottom plate is smooth and the roof pressure
is too large, so as to decide which operation mode to use. If
the roof pressure, broken, uneven floor, you may not use linkage,
support group up operation.
Single frame non automatic control
Operation procedure:
The first step: choose the frame according to the number of 1
keys (select left frame) or 2 keys (which selected digital
frame)
The second step: send operation command:
1) use the keyboard shortcuts to send commands
A drop post
B key shift
C lift column
D key shift + lift base
E key drop column + lift base
F key balance jack
7 button balance jack
8 keys received the first guard plate (for end head for
telescopic beam)
The first 9 key stretch guard plate (for end frame for stretch
shrink beam)
L key pushing
2) and other operations: bring up the corresponding menu item,
send the command SIDESEAL, IN, OUT, side guard board with K key
or M key
LIFTING ON lift the base
SH-SPRAY ON spray
FLIPPER2 IN OUT second retaining panels for extension and
extension
BALANCE IN OUT carries the inter frame jack or end to side guard
plate and extension
Be careful:
1, in the whole process of action, we must continue to press
and hold the corresponding command button, do not let go, let
go of the action, that is, stop.
2, this frame slides, as long as the direct press "L" key, this
frame push slip lasts 5 minutes automatically stop, if you need
to stop early, and then press "L" key.
4, the adjacent automatic sequence (fall - rise -) linkage
control
Operation procedure:
The first step: choose the frame according to the number of 1
keys (select left frame) or 2 keys (which selected digital
frame)
The second step: press the start button
5 、 group automatic control
Operation procedure:
The first step: Select function
* according to the number 9 key - select "automatically up"
function
* according to the number 8 key - "automatically push" function
* according to the number 7 key - "group automatic guard board
function
* according to the number 6 key - select "automatically pull
out function
* according to the number 7 key, the screen shows "FLIN:---",
then click "I" button down one line, the screen shows "FLEX:---"
- select "automatically stretch guard board function.
The second step: set the direction of the group (the direction
of the default group action is near to far)
Press the number 4 keys (grouped on the left of the operating
rack) or the number 5 keys (grouped on the right side of the
operating rack)
The third step: to adjust the direction of the group action,
and then press the number 4 or the number 5 keys
The fourth step: press the start button
6, use the shortcut key to enter the specified menu column
directly
A - directly select the menu "SERVICE (service)" column.
B - directly select the menu "GLOBAL-PARAMETER" (general
parameter) column.
F - directly select the menu "ERROR MESSAGE" (automatic
function error) column.
6 - directly select the menu "CP:---" (Group Auto slide function)
column.
7 - directly select the menu "FLIN:---" (Group Automatic
receive / extension protection board function).
8 - directly select the menu "BP:---" (Group automatic push off
function) column.
9 - directly select the menu "ASQ:---" (automatic drop down,
move up, sequence, linkage function).
7, modify parameters
Operation procedure:
Step 1: make the screen display the desired menu line;
The second step: press the "R" key to enter the modified state;
The third step: modify parameters:
The menu displays parameter items with * symbols: enter the
ideal number, modify the parameters directly.
The menu shows the parameter items without the * sign (for most):
modify the parameters with the "K" key (decrement) or the "M"
key (increment).
The fourth step: press the R button to confirm
8, commonly used operations
1, set the sensor to invalid
If the sensor has problems or damage, you can set them to be
invalid. Operation procedure:
Step 1: move the MEASURED VALUES (sensor measurements) column
with the left and right keys;
The second step: use up and down the key to call up the sensor
menu items
$PROP>> column pressure value (MP)
$CONVEYOR pass Jack travel value (mm)
The $IR SNS value indicates that the controller receives the
signal voltage of the infrared receiver
The third step: under the name of a sensor, press the R key,
the frame is set to invalid. In an invalid state, the R key is
resumed once again.
9. Reset the controller
Operation procedure:
Step 1: press the "A" button to enter the menu SERVICE (service)
column;
The second step: use the down key to transfer the "RESET" item.
Under this item, press the "K" key to reset the controller and
restart the program, just like when the power is on.
10 atresia and sudden stop
Lock: staff to support a long time stay should be implemented
in atresia, blocking method is that the controller of the red
button clockwise 900, the hard frame (atresia can't take orders.
Neither can a command), about adjacent soft lock (do not accept
the order, but to support other issue control commands) the
scope of protection, such as the 3 support staff.
Emergency stop: when any controller on the work surface presses
the emergency stop button, the automatic function is being
stopped immediately, but the adjacent control, automatic spray
and automatic pressure relief can still be operated.
Three, matters needing attention
No matter what mode of operation is used, it must be confirmed
that no one is in or before the scaffold being operated.
Otherwise, the scaffold shall not be operated.
When lifting the column, attention should be paid to whether
the initial support force is reached and the existing problems
should be dealt with in time.
When moving or moving a carrier, the front of the support must
be observed to prevent damage to the cable, the amplifying
telephone, the water pipe and other equipment.
When lifting the column, attention should be paid to the
position of the side guard plate to prevent it from being
damaged.
When operating, should grasp the reasonable height of the
support bracket, the maximum support height should be less than
the design height of 200mm, the minimum support height should
be greater than the design height 300mm.
When the control valve failure or malfunction occurs, we should
carefully find the reasons, troubleshooting in time, or can not
operate the stent.
If the roof or other abnormal conditions are found during the
landing, the bracket should be raised immediately and the frame
can be lowered until it is properly handled.
In order to increase or decrease the height of the mine, a steady
transition must be carried out to maintain a reasonable shape.
If the cycle pressure is encountered in the face, roof
subsidence appears larger, roof caving, spalling, serious
balance cylinder piston rod, frame structure of large amount
of bad situation, must advance up.
发布评论