2024年1月14日发(作者:)
故障实例: 1、RAID5 一块硬盘掉线
2950 在0,1,2 三个硬盘槽位分别接入了 ST 1TB SATA 硬盘,配置成RAID 5 。
开机后发现有一块硬盘指示灯不亮,显示器上并提示如下:
some configured disks have been removed from your system or are no longer
accessible.
please check you cables and also ensure all disk are any key to
continue,or 'C' to load the configuration utility.
按 键盘 上的 C 键后,出现提示如下:
Entering the configuration uility in this state will result in drive configuration
changes .press 'Y' to continue loading the configuration utility or power off your
system and check your cables to ensure all disk are present and reboot
按 键盘 上的 Y 键后
进入RAID配置界面,没有看到在1 号位的 硬盘,提示:MISSING ,RAID 5 状态为 Degraded 然后重启机器后,发现 原来指示灯不亮的硬盘,指示灯开始变为橙色,后又变成绿色
提示: Fw package:6.0.2—0002
2 virtual Driver(s) found on the host adapter
1 virtual Driver(s) Degraded 2 virtual Driver(s) handled by BIOS
foreign configuration(s) found on adapter
press any key to continue or 'C' load the configuration utility or 'F' to import foreign
configuration (s) and continue
然后,在RAID配置界面里将掉线的,导入。后恢复正常后,不久该硬盘又掉线,怀疑硬盘有问题。导入的时间将近4个小时,数据量2G多,硬盘上就光一个RHEL5
定制的系统
RAID 5 更换1块坏硬盘。0,1,2 三块插槽位配置RAID5 。1插槽位的驱动器状态由绿变橙。预报警。现更换1 处的硬盘。
方法1、 在开机状态,机器正常运行情况下,取下有问题的硬盘后,在接入新的同型号,同容量大小的硬盘,此时,可观察到,0,3 插槽位的硬盘指示状态灯亮绿色,活动状态灯绿色闪烁。1插槽位硬盘指示状态灯绿色闪烁,活动状态灯不亮。此时,1 插槽位的硬盘正在重建数据。等0,1,2 驱动器硬盘指示状态等全绿,稳定亮起时。RAID 5 重建完成
方法2、 关机,取下坏硬盘。在接入新的同型号,同容量大小的硬盘。开机,后 进入 RAID的配置界面,在 手工 重建 新硬盘的数据
发布评论