2024年2月21日发(作者:)
030.0122.03.0
S1 TITAN/TRACER 5/CTX
Bruker Toolbox Installation Guide
1.7.0.128
Bruker Toolbox Installation Manual
030.0122.03.0
This page intentionally left blank.
2 of 18
Bruker Toolbox Installation Manual
Table of Contents
1. Introduction and Requirements ..........................................................................................................................5
2. Setting User Access Control .................................................................................................................................6
3. Installing Bruker Toolbox ....................................................................................................................................8
4. Connecting the Instrument ............................................................................................................................... 12
Appendix A C++ Redistributable ............................................................................................................................ 14
Appendix B
Appendix C
Installing the Driver ........................................................................................................................... 15
Working with a Firewall ..................................................................................................................... 17
030.0122.03.0 3 of 18
Bruker Toolbox Installation Manual
030.0122.03.0
This page intentionally left blank.
4 of 18
Bruker Toolbox Installation Manual
1. Introduction and Requirements
Description
Microsoft
requirements
.NET
IP address
Contacting
Bruker
030.0122.03.0
Bruker S1 TITAN, TRACER 5, and CTX instruments can be operated remotely from a PC with –
Windows operating system 7, 8.1, or 10.
Bruker Toolbox, part number 710.0042, included on the Bruker USB stick User Manuals,
Toolbox, Videos, part number 160.0209.
This manual describes how to install Bruker Toolbox onto a PC. Windows administrator rights
are required.
Bruker Toolbox software requires appropriate Microsoft support packages –
.NET 4.6.2 or higher.
Visual C++ Redistributable package.
If the available version of .NET is not 4.6.2 or higher, the installation process is exited. To install
the latest version, go to /en-us/download/?id=55170 or
search Google for “.NET download.”
The S1 TITAN, TRACER 5, and CTX default IP address is 192.168.137.139. To change the IP address,
from the Ready to Test screen on an instrument, tap Utilities -> Connections -> Connection ->
USB tab or Wireless tab. See the Supervisor Manual, Bruker document 030.0113.
Email: **********************Address: 415 N. Quay Street
Phone: +1 (509) 783-9850, Option 4 Kennewick, WA 99336 USA
Web: /hhxrf
5 of 18
Bruker Toolbox Installation Manual
2. Setting User Access Control
Description
Process
030.0122.03.0
Before installing Bruker Toolbox, the User Access Control must be set.
To change User Account Control settings in Windows –
Step Action Result
1 On the PC, open the Control Panel. The Control Panel window is displayed.
2 Select User Accounts. The User Accounts window is displayed.
3 Click Change User Account Control settings. The User Account Control Settings
dialog box is displayed.
4 Drag the slider down and click OK. The change is saved and the dialog box
is closed.
6 of 18
Bruker Toolbox Installation Manual
030.0122.03.0
7 of 18
Bruker Toolbox Installation Manual
3. Installing Bruker Toolbox
Description
This section describes how to install Bruker Toolbox onto a PC. The two different methods are based
on whether Toolbox was installed previously. If so, the old version is automatically uninstalled, with
one exception, as described below.
In the case of Bruker Toolbox version 1.6.0.110, before a new version can be installed, version
1.6.0.110 must be explicitly uninstalled using Windows Start -> Control Panel -> Programs and
Features. Right click Bruker Toolbox and click Uninstall.
Exception:
version
1.6.0.110
Process if not
installed
previously
030.0122.03.0
To install Bruker Toolbox onto a PC for the first time –
Step Action Result
1 Disconnect the instrument from the PC.
2 Install the provided USB stick, part number The Bruker Instrument Tools and Bruker
160.209. Navigate to and double-click the RemoteCtrl Installation dialog box is displayed.
Bruker Toolbox file name or download from
the Bruker website.
3 Click Next. The Installation Folder dialog box is displayed.
8 of 18
Bruker Toolbox Installation Manual
Process if
previously
installed
030.0122.03.0
4 Accept the default folder by clicking The Installing Files progress box is displayed
Next. briefly, then the Bruker Instrument Tools and
OR
Bruker RemoteCtrl Install Successful dialog
Change the destination folder by –
box.
1. Clicking Browse…
2. From the Browse for Folder dialog
If a previous version is already installed, the
box, selecting a folder and clicking
Uninstall Previous Version dialog box is
OK.
displayed. See the following table for steps.
3. Clicking NEXT.
5 Click Finish. Bruker Instrument Tools and Bruker
RemoteCtrl icons are displayed on the desktop.
Step Action Result
1 Starting at Step 4 of the previous After a moment, the Bruker Instrument Tools and
table, click OK on the Uninstall Bruker RemoteCtrl Uninstallation! dialog box is
Previous Version dialog box. displayed.
9 of 18
Bruker Toolbox Installation Manual
030.0122.03.0
2 Click Next. A progress bar is displayed briefly, then the Uninstall
Successful dialog box.
3 Click Finish. The Installing Files progress box is displayed briefly,
then the Bruker Instrument Tools and Bruker
RemoteCtrl Install Successful dialog box.
10 of 18
Bruker Toolbox Installation Manual
Cancelling
uninstallation
030.0122.03.0
4 Click Finish. Bruker Instrument Tools and Bruker RemoteCtrl icons
are displayed on the desktop.
To cancel the uninstallation, click Cancel on an Uninstalling dialog box. The following dialog box
is displayed.
Click OK.
11 of 18
Bruker Toolbox Installation Manual
4. Connecting the Instrument
Description
Process
030.0122.03.0
To finalize the driver installation for the first time only, connecting the instrument to the PC
through a USB cable is recommended.
To connect the instrument to the PC –
Step Action Result
1 Power on the PC and the instrument.
2 Connect the instrument to the PC with a USB cable
(Bruker part number 160.0012.01.0).
3 On the PC, double-click the Bruker RemoteCtrl icon. The Bruker RemoteCtrl window
is displayed.
4 Click File. A dropdown list is displayed.
5 Click Connect. The Connect popup is displayed.
6 Log into the instrument in Supervisor mode and The Ready to Test screen is
follow instructions on the instrument screen. The displayed.
default password is 54321.
7 On the instrument, tap Utilities -> System Setup The Connection screen is displayed.
-> Connections.
12 of 18
Bruker Toolbox Installation Manual
8
After a few minutes, the first
time the PC and instrument are
connected after the first time
the driver is installed, the
Windows Security Alert
window is displayed on the PC.
On the instrument, select USB Enable and click OK.
9 Check the box for Public network, such as … and
click Allow access.
10 On the PC, click the instrument name and click OK.
If not, see Working with a
Firewall on page 17.
After a few seconds, the
instrument serial number is
displayed in the Connect dialog
box.
After a few seconds, the
instrument screen is displayed
on the PC.
030.0122.03.0
13 of 18
Bruker Toolbox Installation Manual
Appendix A C++ Redistributable
C++ The installation process should include automatic installation of .dll files. If not, see the following.
Redistributable
030.0122.03.0
When accessing Bruker RemoteCtrl, if an error message stating that and/or
are missing is displayed, Visual C++ Redistributable for Visual Studio 2015 must be
installed.
To install and/or –
Step Action Result
1 Navigate to The download page is
/en-us/download/?id=48145. displayed.
2 Click the red Download button. A new page is
displayed.
3 Select the vc_ checkbox and click Next. vc_ is
available at the bottom
Note: x86 version is required even on a 64-bit OS. of the browser.
4 Click Save and Run. The installation
window is displayed.
5 Read, and click the box to agree to, the license terms and Libraries are installed
conditions. Click Install. in the appropriate
location.
14 of 18
Bruker Toolbox Installation Manual
Appendix B Installing the Driver
Description The installation process should include automatic installation of the driver. If not, see the
Process
030.0122.03.0
following.
This section describes how to manually install the driver for Windows operating systems 7, 8.1, or
10. For subsequent installations of Bruker Toolbox, these steps are not required as the driver is
automatically installed.
To install the driver –
Step Action Result
1 Power on the PC and the instrument.
2 Connect the instrument to the PC with a USB
cable (Bruker part number 160.0012.01.0).
3 Navigate to the folder containing Bruker
Toolbox. The default location is
C:Programs Files (x86)BrukerBruker
Toolbox.
4 Right click on the file name appropriate to the A dropdown list is displayed.
operating system.
Windows 7 –
Windows 8.1 and 10 -
5 Click Install. The Windows Security dialog box is
displayed.
6 Select Install this driver software anyway. The message Device driver software
installed successfully is displayed.
If the message Device driver
software was not successfully
installed, unplug the USB cable, wait
15 seconds, and plug it in again.
15 of 18
Bruker Toolbox Installation Manual
030.0122.03.0
16 of 18
Bruker Toolbox Installation Manual
Appendix C Working with a Firewall
Description The installation process should include automatic access through a firewall. If not, see the
Port numbers
Process
030.0122.03.0
following.
A firewall may interfere with the connection between a PC and an instrument and prevent the
instrument serial number from displaying in the Connect dialog box. This section describes how
to work around a firewall by deleting certain firewall rules.
Fixed port numbers are 55000, 55101, 55102, 55203. Artax uses 55204. Data Stream uses 55001,
55204, 55205, and 55500. These must stay open.
To delete firewall rules that block Bruker programs –
Step Action Result
1 On the PC, open the Control Panel. The Control Panel window is displayed.
2 Click Windows Firewall. The Windows Firewall window is
displayed.
17 of 18
Bruker Toolbox Installation Manual
030.0122.03.0
3 Click Allow a program or feature through The Allow programs to communicate
Windows Firewall. through Windows Firewall window is
displayed.
4 For each program to be deleted, highlight The window reflects the changes.
the name and click Remove. Remove the
follow programs:
All entries that start with S1RemoteCtrl,
e.g., S1RemoteCtrl, S1 RemoteCtrl,
S1 .
S1 Sync.
Bruker Instrument Tools.
Bruker RemoteCtrl.
5 Close all windows.
6 Repeat the steps in Connecting the
Instrument on page 12 for both Bruker
RemoteCtrl and Bruker Instrument Tools.
18 of 18
发布评论