OMRONQuick Start

TerminologyProject :

Block:Network:A project is a file that contains all of the ladder logic, PLC setup, and

communication settings associated with a particular PLC program.A section of ladder logic that is grouped together because of a common theme

is referred to as a block. Using blocks is a common method of organizing a

project into individual functional entities without affecting the execution of the

ladder logic (i.e. alarms, diagnostics, initialization, etc.). Blocks can be named

and referred to by their name for easy cut-and-paste editing.A single rung of ladder logic is referred to as a network. As with Blocks,

networks can also be named and referred to by name when programming for

easy cut-and-paste editing.1

Objective #1: Installing OMRON SYSWIN SoftwareBeginning the InstallationNote: This Installation assumes that Windows 3.X is being used, or Windows 95 with Syswin V3.0

and a V3.0 Token. If you are using Windows NT, or Windows 95 and a V2.1 Token, thisinstallation can be used for Demonstration mode or CPM1 Only mode. To move a token underthese circumstances , please consult the Syswin manual for instructions regarding the DOStoken 1:Step 2:Insert the Syswin Installation Disk #1 into the floppy drive.a. Windows 3.X, Windows NT the Windows Program Manager Click on File then click on RunFrom the Command Line box type a:s 95Click on Start then RunFrom the Open box type a:SetupStep 3:Step 4:Press or click the SYSWIN Setup window click on Continue or press .

Step 5:In the next SYSWIN Setup window click on English then click on Continue orpress .2

Step 6:In the next SYSWIN Setup window click on Continue or press to install SYSWIN

in the C:SYSWINx directory. To change the directory, type the desired installation location

in the Path box then click on Continue or press .Step 7:In the next SYSWIN Setup window, click on the type of installation 1 only - Full functionality of the software for the CPM1 PLC tration - Evaluation mode for all applicable OMRON PLC’s. In demonstration mode you can not go online, print, or save a l Token - Full functionality of the software for all applicable OMRON PLC’s. Note: Only choose Install Token if you are using Windows 3.X, or

Windows 95 with Syswin V3.0 and a V3.0 Token. Windows NT users,

and Windows 95 users with a V2.1 must consult the Syswin manual for

instructions on the use of the DOS token mover..3

Step 8:Step 9:If you have not chosen Install Token the installation is complete, otherwise the SYSWIN Token Mover window click on the Activate Syswin 10:When the Token movement is complete, click on OK in the Token Movement 11:Click on Exit. The installation is now complete.4

Objective #2: Create a New ProjectBegin a New ProjectStep 1:With the mouse, click on File then click on New 2: Select the PLC Type you are 3: Press or click a Normally Open ContactStep 1: Click on Normally Open contact from the drawing tools on the left side of the 2: Move the mouse pointer to the middle of the black cursor box and click once. This places the

3:In the Contact window, enter the contact address 000.00 .Step 4:Press or click a Normally Open CoilStep 1:Click on the Normally Open output on the drawing tools on the left side of the 2: Move the mouse pointer to the middle of the black cursor box and click once. This places

the 3:In the Output window, enter the coil address 001.00 .5

Step 4:Press or click a New NetworkStep 1:Step 2:With the mouse, click on Block then click Insert the Insert Network window, select ut àStep 3:Press or click an End StatementStep 1: Click on Function from the drawing tools on the left side of the 2: Move the mouse pointer to the middle of the black cursor box and click once. This places the

3:In the Function window, type either 01 (for function 01) or type 4:Press or click OK.6

Objective # 3: Transfer Program to PLCEstablish Communications with PLCStep 1:Determine if the software is currently “online” with the PLC in one of several the telephone icon on the toolbar is on the hook, the PLC is offline. If the telephone iconis off the hook, the PLC is e à

on Online. If the window appears similar to the window on the left, the PLCis online. If the windows is similar to the window on the right, the PLC is à

Step 2:Step 3:If the PLC is online skip to “Place the PLC in Monitor Mode”If not, Click on Project then click on the Port to match the serial Port on the the communications parameters that match the PLC default for many OMRON PLC’s is Baud of 9600, Unit # 00 and Protocol ofASCII 7 bit Even Parity 2 4:Step 5:Click on Test the Status window indicates Connected, then the PLC is not, consult the operations manual for the PLC to identify the communications on the PLC in Monitor ModeStep 1:Step 2:Click on Online, then on on Monitor. This places the PLC in monitor ut à7

Step 3:Press or click ad the Program to the 1:Step 2:Click on Online, then click on the Download Program to PLC window, check the box marked Clear Program Not check the Expansion Functions or Memory Allocation 3:In the Syswin Question window, Click Yes, or press .This changes the PLC to Program mode 4:In the next Syswin Question window, Click Yes, or press .This changes the PLC back to Monitor 5:In the Download window, click OK or press .The download process is now complete.8

Objective # 4: Force I/O Bits

Enter Addresses to Force

Step 1:Step 2:Step 3:Step 4:Click on Online, then click .In the first Address field enter the address 0.00 .To the right of the address field there is an Action field. With the mouse, click on the down

arrow and choose Force the right of the Action field, there is a Write Check box. With the mouse, click on this box.A check mark indicates this action will be performed when the force is executed. The final

result should resemble the window Force DataStep 1:Step 2:PLC

Step 3:Step 4:With the mouse, click on the button. This operation executes the forcing in the

in the status window at the bottom of the display that it says “Write - OK.” Thisindicates the bit has been forced and you should be able to see the appropriate light on closing this window you must click on the button. This button releases allof the forced bits and is necessary to resume normal PLC the mouse, click on the button.9

Objective # 5: Monitor DataDisplay Desired Memory AreaStep 1:Step 2:With the mouse, click on Editors, then click on Data display on

the screen. from the memory area buttons on the left side of Shortcut→v2.1v3.0Step 3:Step 4:In the range window, you can specify All or Partial memory area display. Choose or click utMonitor Displayed Memory Area Step 1:Click on Online, then click on Monitoring. You should

→Step 2:see the cursor change from an arrow to an arrow with alightening bolt indicating the display is being your input on again by repeating objective # 2 and watchthe bits change on the monitor screen in the background.10