2024年3月30日发(作者:)

SPDC12L00010

10 A DC-DC converter module

Features

Complete switch mode power supply

10 A max output current

Input voltage range from 1.8 V to 14 V

Supply voltage range from 4.5 V to 14 V

Fixed or adjustable output voltage range from

to 0.6 V to 5 V

Fixed frequency voltage mode control

Ultrafast transient response

Soft-start and inhibit

Selectable UVLO threshold (5 V or 12 V bus)

Master/slave synchronization with 180° phase

shift

Pre-bias start-up capability

Selectable source/sink or source only

capability after soft-start

Applications

Power Good output with programmable delay

Overvoltage protection with selectable

latched/not-latched mode

Overcurrent protection

Thermal shut-down

l

o

s

b

O

Table 1.

Operating temperature range -40 °C ÷ 85 °C

e

t

e

o

r

P

c

u

d

O

-

)

s

(

t

e

l

o

s

b

Blade servers

RAID systems

P

t

e

d

o

r

)

s

(

t

u

c

Network routers

Cellular base stations

Industrial equipment

Test instrumentation

Medical diagnostic equipment

Distributed point of load

Device summary

Output voltage

[V]

0.6 ÷ 5

Input voltage

[V]

1.8 ÷ 14

Output ripple

[mVpp]

40

Peak efficiency

[%]

93

Notes

Progr. output

voltage

Order code

SPDC12L00010

September 2009Doc ID 15103 Rev 31/29

29

/

ContentsSPDC12L00010

Contents

1

2

Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Pin settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

2.1

2.2

Pin connection and mechanical data (dimensions in mm) . . . . . . . . . . . . . 5

Pin description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

3Maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

3.1

3.2

3.3

Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Thermal data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Thermal de-rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

4Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

4.1Typical performance characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

5Application information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

5.1

5.2

5.3

5.4

5.5

Input voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Auxiliary voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Inhibit function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Soft-start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Multiple units synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Power Good signal and Power Good delay . . . . . . . . . . . . . . . . . . . . . . . 19

Oscillator setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Current sink-mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Undervoltage lock out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Program setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Voltage sensing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Output voltage programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Additional loop compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Output over voltage protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Current limitation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Thermal shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Signal ground and power ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

l

o

s

b

O

e

t

e

5.6

5.7

5.9

5.10

5.11

5.12

5.13

5.14

5.15

5.16

5.17

5.8

o

r

P

c

u

d

O

-

)

s

(

t

e

l

o

s

b

P

t

e

d

o

r

)

s

(

t

u

c

2/29Doc ID 15103 Rev 3

/