2024年4月5日发(作者:)

三菱系统简明调试手册

目录

一:E60,M64的联接.....................................................................................................................2

1:E60-NC联接............................................................................................................................2

2:基本I/O联接...........................................................................................................................4

3:6

4:伺服系统的联接.......................................................................................................................8

5:E60,M60系列系统联接总图..................................................................................................9

二:外围线路的检查及上电注意事项..........................................................................................12

三:参数的设定...............................................................................................................................12

1:基本参数的设定.....................................................................................................................12

2:轴参数的设定.........................................................................................................................14

3:原点复归参数.........................................................................................................................14

4:伺服参数的设定.....................................................................................................................15

5:主轴参数的设定.....................................................................................................................17

6:机械误差.................................................................................................................................18

7:18

8:巨程式,位置开关详见操作手册........................................................................................19

四.PLC程序的输入......................................................................................................................19

1:PLC4B格式PLC传输..........................................................................................................19

2:GPPW格式PLC程序输入...................................................................................................20

3:PLC系统部分运行测试........................................................................................................21

五:资料备份及恢复.......................................................................................................................22

1:RS-232C传输方式.................................................................................................................22

2:资料备份卡存储方式.............................................................................................................23

六:附录...........................................................................................................................................24

1:伺服参数标准设定表(未列明的系列请参照手册)........................................................24

2:主轴参数(未列明的请参照手册)....................................................................................25

3:SVJ2伺服参数的优化...........................................................................................................27

4:模具加工经验参数及高速高精度的使用............................................................................29

5:三菱相关软件.........................................................................................................................30

1

三菱系统简明调试手册

一:

E60

M64

的联接

1:E60-NC联接

(1)E60-NC(FCU6-MU071)接口图:

DCIN

CRT

CF01

EMG

LCD

CF10

NCKB

RIO

NCLD1HANDLESIO

端口说明

DCIN

CF01

EMG

CF10

RIO

NCLD1

HANDL

SIO

CRT

LCD

NCKB

NC直流24伏输入

断电源检测

紧急停止输入

联接基本I/O单元

联接远程I/O单元

NC数码显示

手摇脉冲发生器

RS232C设备

连接CRT显示单元(DUE71)

联接液晶显示单元(DUT11)

系统键盘的联接

2

配置电缆

F070

备注

使用开关稳压电源端(24V±

5%,2A)

内部有源输出,外部电源禁入F120

F010

R211

正常显示“—”

F023/F024

F320/F321

F034

F590

F090

F053

F023/F024为5V手轮线

F320/F321为12V手轮线

外部计算机要与机床共地