2024年4月6日发(作者:)
Brochure | EN
Frequency inverter
0.25 ... 132 kW
As easy as that.
2
Lenze · frequency inverter · 01/2020
Lenze inverter –
universally applicable.
A multifunctional all-rounder applicable for all cases – just another way to perfectly
describe the frequency inverter. Thanks to a high number of integrated functions,
network interfaces and a simple parameter setting, the inverter is suitable for both
mechanical engineering and apparatus construction.
Lenze inverters are an important component in modern drive solutions which
range from the cloud via control systems to motors and geared motors.
Typical application fields
• Textile machines
• Materials handling technology
• Packaging technology
• Forming technology
• Consumer goods machines
• Industrial air conditioning technology (pumps, fans & compressors)
• Construction machines
• Access control
• etc.
Features
• The modular and scalable concept allows the selection of the inverter required
for the respective application.
• The compact design allows an efficient installation for applications where space
means money.
• Easy installation and OEM friendly as standard. Robust design for reducing
cabling costs in large installations.
• Interaction for each application level – from simple to complex!
• Energy-efficient and high functionality
The benefits for you
• Lower investment costs
• Less control cabinet space and costs
• More productivity
• More time for innovation
• Sustainability
• Reliability
Lenze · frequency inverter · 01/2020
3
Features at a glance.
Compact design
In mechanical engineering and
apparatus construction, space is limited
and expensive. Thus, Lenze inverters
are extremely compact to implement
solutions and save costs.
The i5.0 devices impress with a space-
saving design with a width of 60 mm
(up to 4.0 kW) and a depth of just
130 mm (up to 11 kW). Moreover, the
devices can be be mounted directly
next to each other without derating.
4
Flexibility
Lenze offers one of the most com-
prehensive solution portfolios for
mechanical engineering and apparatus
construction.
No matter which power, mains volt-
ages, communication interfaces or
diagnostics options – our product range
has the right solution optimized for the
requirement.
User-friendliness
A good usability of the devices ranging
from installation to service reduces
working time, costs and errors in
handling. This makes installation with
keyhole mounting and plug-in terminals
particularly convenient.
Programming your application is opti-
mized for all application levels.
The smartphone app via WLAN pro-
vides only one of numerous interfaces
to the device.
Lenze · frequency inverter · 01/2020
Centralized/
decentralized
Many machines and apparatus provide
enough space for a compact inverter
such as the i510 or i550.
If your machine requires a lot of space,
has a modular design or the space in
the control cabinet is limited, we rec-
ommend a decentralized installation
close to the motor. This serves to avoid
the installation costs expensive
motor cables.
In many applications, a mixture of cen-
tralized and decentralized drive tech-
nology is advisable. Fortunately, the
i5x0 cabinet and i5x0 protec inverters
show the same drive behavior.
Lenze · frequency inverter · 01/2020
IO-Link
For an intelligent integration of
sensors and actuators, IO-Link is used
increasingly. If the system already con-
tains an IO-Link master, inverters can
be integrated cost-effectively.
With the i550, Lenze is the first man-
ufacturer to fulfil the IO-Link standard
V1.1. This allows the inverter to be
automatically parameterized for
serial commissioning or in the event
of service.
Robustness
Applications, for instance in the timber
industry or intralogistics, place high
demands on the components of the
machines regarding robustness. Harsh
environments are no problem for the
i550 protec.
Featuring the IP66 degree of protection
(Indoor & Outdoor NEMA 4X), the tech-
nology inside the housing is protected
against dust and the device can be
safely cleaned using water jets.
5
6
Lenze · frequency inverter · 01/2020
Configurable
for all requirements.
Frequency inverter
Lenze offers a comprehensive inverter portfolio for mechanical engineering and
EASY Product Finder
apparatus construction. Whether control cabinet mounting, motor mounting or
decentralized mounting with terminals or with complete connection technology
– our independent advice is geared towards finding the best solution for your
specific case.
The Lenze EASY Product Finder helps you configure your required frequency
inverter type in next to no time. In addition, you can retrieve all important
technical details such as data sheets, CAD data and EPLAN data.
i510 cabineti550 cabinet
• Basic inverter IP20 • Standard inverter IP20
NEMA Open Type• Universally applicable
• 0.25 ... 11 kW• 0.25 ... 110 kW
i550 protec8400 motec
• Standard inverter IP31 or IP66• Standard inverter for motor or
• Universally applicablewall mounting IP65
• 0.37 ... 11 KW (expansion up to 75 kW • Various connector options for power and
planned)signals for minimum installation expenses
• 0.37 ... 7.5 kW
Lenze · frequency inverter · 01/2020
7
i510 and i550 cabinet
8
i510 and i550 cabinet form the inverter series for the control cabinet in a power
range of 0.25 ... 132 kW. They are distinguished by the following attributes – slim
design, scalable functionality and exceptionally user-friendly. The simple i510
from 0.25 ... 11 kW and the universally applicable i550 from 0.25 ... 110 kW have
the same DNA but differ in functionality and are optimized for a good price/
performance ratio.
Highlights
• Space saving design: 60 mm wide (up to 4 kW), 130 mm deep
(up to 11 kW), with zero-clearance mounting
• Innovative interaction options enable better set-up times than ever.
• The wide-ranging modular system enables various product configurations
depending on machine requirements
• Optionally with "Safe Torque Off (STO)" with SIL 3 (ISO 13849-1 (EN 954-1) ) and
Performance Level e (EN 62061/EN 61800-5-2)
• Flexibility: Get the i550 as a complete device or in individual components
(Power Unit, Control Unit and Safety Unit)
Lenze · frequency inverter · 01/2020
i510 cabinet
·
Power range
0.25 ... 11 kW
Mounting
·
-
Installation
·
Degree of protection
·
IP20
NEMA Open Type
-
-
-
-
·
Approvals
CE, UL, CSA, EAC, RoHS
Connections
·
-
·
1 AC 230 V
·
1/3 AC 230 V
·
3 AC 230 V
3 AC 400/480 V
·
-
Basic I/O:
5x digital input
1x digital output
-
-
-
-
·
-
Basic I/O:
2x analog input
1x analog output
-
-
·
-
·
no
1x NO/NC relay (24 DC max. 2 A; 240 AC max. 3 A)
-
·
-
·
Spring terminals
Evaluation of motor PTC
·
Overload behavior
200 % for 3 s; 150 % for 60 s
Motor controls
·
-
·
Sensorless vector control for synchronous motors (up to 22 kW)
·
Sensorless vector control (SLVC)
·
Energy saving function (VFC-Eco)
V/f characteristic control linear/square-law (VFC plus)
-
·
Functions
·
DC-injection braking
Brake management for brake control with low
rate of wear
·
-
·
S-ramps for smooth acceleration and deceleration
·
Flying restart circuit, PID controller
DC connection
Safety engineering
-
·
Networks
CANopen, Modbus RTU
·
Ambient temperature during operation
3K3 (-10 ... +55 °C) EN 60721-3-3 (derating of 2.5 %/°C above 45 °C)
Lenze · frequency inverter · 01/2020
i550 cabinet
·
Power range
0.25 ... 110 kW
·
Mounting
·
Wall mounting
Installation
·
Degree of protection
·
IP20
NEMA Open Type
-
-
-
-
·
Approvals
CE, UL, CSA, EAC, RoHS
·
Connections
·
1 AC 120 V
·
1 AC 230 V
·
1/3 AC 230 V
·
3 AC 230 V
3 AC 400 V/480 V
·
-
Standard I/O
5x digital input
1x digital output
·
-
Application I/O:
7x digital input
1x digital output
·
PNP/NPN logic
Standard I/O
2x analog input
·
1x analog output
Application I/O:
2x analog input
·
2x analog output
·
Frequency input: 0 … 100 kHz
·
1x NO/NC relay (24 DC max. 2 A; 240 AC max. 3 A)
External 24 V supply and internal 24 V power supply unit
·
-
·
Spring terminals, plug-in
Evaluation of motor PTC
·
Overload behavior
200 % for 3s; 150 % for 60s
·
Motor controls
·
Servo control (SC-ASM) with feedback
·
Sensorless vector control for synchronous motors (up to 22 kW)
·
Sensorless vector control (SLVC)
·
Energy saving function (VFC-Eco)
·
V/f characteristic control linear/square-law (VFC plus)
V/f characteristic control with feedback
·
Functions
·
DC-injection braking
Brake management for brake control with low
·
rate of wear
·
Dynamic braking through brake resistor
·
S-ramps for smooth acceleration and deceleration
·
Flying restart circuit, PID controller
DC connection
·Safety engineering
Safe Torque Off (STO)
·
Networks
CANopen, Modbus RTU, Modbus TCP, IO-Link, EtherCAT,
EtherNET/IP, PROFIBUS, PROFINET, POWERLINK
·
Ambient temperature during operation
3K3 (-10 ... +55 °C) EN 60721-3-3 (derating of 2.5 %/°C above 45 °C)
9
i550 protec
i550 protec uses the same tried-and-tested technology used in i550 cabinet and
only differs in terms of a higher degree of housing protection with an adapted
design. If your machine requires a lot of space, has a modular design or the space
in the control cabinet is limited, the universally applicable i550 protec (IP31
and IP66 degree of protection) from 0.37 kW ... 11 kW (expansion up to 75 kW
planned) is the ideal solution for a decentralized installation close to the motor.
Highlights
• IP66 degree of protection (Indoor & Outdoor NEMA 4X) with protection against
high pressure water jets from any direction and dust tightness allows for use in
harsh environment applications
• USB Micro diagnostic interface on board
• Optionally available with extension box with or without service switches
• Optionally available with keypad or WLAN diagnostic module
• Optionally available with "Safe Torque Off (STO)" with SIL 3 (ISO 13849-1
(EN 954-1) ) and Performance Level e (EN 62061/EN 62061/EN 61800-5-2)
10
Lenze · frequency inverter · 01/2020
i550 protec
·
Power range
0.37 ... 11 kW
·
Mounting
·
Wall mounting
Installation
·
Degree of protection
·
IP31
·
NEMA 1
·
IP66
NEMA 4 x
-
-
·
Approvals
CE, UL, CSA, EAC, RoHS
·
Connections
·
1 AC 120 V
·
1 AC 230 V
·
1/3 AC 230 V
·
3 AC 230 V
·
3 AC 400/480 V
·
3 AC 480 V/600 V
Standard I/O:
5x digital input
1x digital output
-
-
-
-
·
PNP/NPN logic
Standard I/O:
2x analog input
1x analog output
-
-
·
-
·
Frequency input: 0 … 100 kHz
·
1x NO/NC relay (24 DC max. 2 A; 240 AC max. 3 A)
External 24 V supply and
·
internal 24 V power supply unit
·
Spring terminals
Evaluation of motor PTC
·
Overload behavior
200 % for 3 s; 150 % for 60 s
·
Motor controls
·
Servo control (SC-ASM) with feedback
·
Sensorless vector control for synchronous motors (up to 22 kW)
·
Sensorless vector control (SLVC)
·
Energy saving function (VFC-Eco)
·
V/f characteristic control linear/square-law (VFC plus)
V/f characteristic control with feedback
·
Functions
·
DC-injection braking
Brake management for brake control with low
·
rate of wear
·
Dynamic braking through brake resistor
·
S-ramps for smooth acceleration and deceleration
·
Flying restart circuit, PID controller
DC connection
·
Safety engineering
Safe Torque Off (STO)
·
Networks
CANopen, Modbus RTU, Modbus TCP, IO-Link, EtherCAT,
EtherNET/IP, PROFINET
·
Ambient temperature during operation
3K3 (-10 ... +55 °C) EN 60721-3-3 (derating of 2.5 %/°C above 45 °C)
Lenze · frequency inverter · 01/2020
11
8400 motec
12
The 8400 motec is a frequency inverter for decentralized installation from
0.37 ... 7.5 kW in IP65. In the three basic variants for motor mounting, wall
mounting or wall mounting with service switch, it already offers a high degree of
flexible solutions. Wherever the focus is on a safe and fast installation of drives, the
8400 motec is the most beneficial solution, e.g. in spatially distributed applications.
Motor mounting:
In the case of motor mounting, the 8400 motec can be operated without derating
regardless of the alignment. Compact solution with Lenze MF motor (120 Hz).
Wall mounting:
Compact and flexible solution for wall mounting in IP65.
Wall mounting with service switch:
Wall-mounted device with 3 maintenance switches. Options for maximum
flexibility in IP54.
Highlights
• Compact design
• High degree of functionality, e.g. integrated brake rectifier
• M12 signal connector for fieldbuses, IOs, external 24 V supply and STO
• High variety of mains plugs for Harting Q4/2 (single or double),
M15 or QUICKON QPD
• Wall mounting without derating
Lenze · frequency inverter · 01/2020
8400 motec
·
Power range
0.25 ... 7.5 kW
·
Mounting
·
Wall mounting
Motor mounting
·
Degree of protection
·
IP66
IP54 (with switching unit)
-
-
-
-
·
Approvals
CE, UL, CSA, EAC, RoHS
Connections
-
-
-
·
-
3 AC 400/480 V
·
-
Standard I/O:
5x digital input
1x digital output
1 inverter enable
-
-
-
PNP/NPN logic
-
-
-
-
-
·
-
·
Frequency input: 0 … 10 kHz
·
1x NO/NC relay
External 24 V supply
together with Ethernet-based fieldbuses and PROFIBUS
·
-
Evaluation of motor PTC
·
Overload behavior
200 % for 3 s; 150 % for 60 s
·Motor controls
·
-
·
Sensorless vector control for synchronous motors
·
Sensorless vector control (SLVC)
·
Energy saving function (VFC-Eco)
V/f characteristic control linear/square-law (VFC plus)
V/f characteristic control with feedback
·
Functions
·
DC-injection braking
Brake management for brake control with low rate of wear
·
with integrated brake rectifier
·
Dynamic braking through brake resistor
·
S-ramps for smooth acceleration and deceleration
Flying restart circuit, PID controller
-
Safety engineering
Safe Torque Off (STO)
·
Networks
CANopen, EtherCAT, EtherNET/IP, PROFIBUS, PROFINET,
ASi
·
Ambient temperature during operation
3K3 (-30 ... +55 °C) EN 60721-3-3 (derating of 2.5 %/°C above 45 °C)
Lenze · frequency inverter · 01/2020
13
Technical data
i510 cabinet inverter
Connection to 230 V mains
Conformities
Approvals
Energy efficiency
Degree of protection
Power systems
Mains switching
Operation with
residual current
circuit breaker
Max. cable length for
EMC
Switching frequencies
Max. ambient
temperature
Max. output
frequency
Overload capacity
Rated power
[kW]
i510-C0.25/230-1
i510-C0.37/230-1
i510-C0.55/230-1
i510-C0.75/230-1
i510-C1.1/230-1
i510-C1.5/230-1
i510-C2.2/230-1
i510-C0.25/230-2
i510-C0.37/230-2
i510-C0.55/230-2
i510-C0.75/230-2
i510-C1.1/230-2
i510-C1.5/230-2
i510-C2.2/230-2
i510-C4.0/230-3
i510-C5.5/230-3
0.25
0.37
0.55
0.75
1.1
1.5
2.2
0.25
0.37
0.55
0.75
1.1
1.5
2.2
4
5.5
Open type
TT, TN
IT
CE
EAC
RoHS 2
UL
US
Class IE2
IP20
C
2014/35/EU, 2014/30/EU
TR TC 004/2011, TP TC 020/2011
2011/65/EU
UL 61800-5-1, CSA 22.2 No. 274
EN 50598-2
EN 60529 (except in the wire range of terminals)
NEMA 250 (type 1 protection against accidental contact only)
Only in UL-approved systems
Voltage to earth: max. 300 V
Apply the measures described for IT systems!
3 x within one minute possible
Up to 2.2 kW 30 mA
Category C2
Category C3
20 m (≤0.37 kW max. 15 m)
≥35 m (≤0.37 kW max. 15 m)
2, 4, 8, 16 kHz. The rated output currents apply at 45 °C and
switching frequencies of 2 and 4 kHz, and at 40 °C and switching frequencies of 8 and 16 kHz
55 °C (derating of 2.5 %/°C above 45 °C)
0 Hz ... 599 Hz
200 % for 3s; 150 % for 60s
Mains voltageRated output
Weight
rangecurrent
[V][A][kg]
1-phase inverter with integrated RFI filter
1.70.75
2.40.75
3.20.95
1/N/PE AC
170 V ... 264 V
4.20.95
45 Hz ... 65 Hz65 Hz
61.35
71.35
9.61.35
1/3-phase inverter without integrated RFI filter
1.70.75
2.40.75
1/N/PE AC or
3.20.95
3/PE AC
4.20.95
170 V ... 264 V
61.35
45 Hz ... 65 Hz
71.35
9.61.35
3-phase inverter without integrated RFI filter
3/PE AC
16.52.1
170 V ... 264 V
232.1
45 Hz ... 65 Hz
Dimensions
(h x w x d)
[mm]
155 x 60 x 130
155 x 60 x 130
180 x 60 x 130
180 x 60 x 130
250 x 60 x 130
250 x 60 x 130
250 x 60 x 130
155 x 60 x 130
155 x 60 x 130
180 x 60 x 130
180 x 60 x 130
250 x 60 x 130
250 x 60 x 130
250 x 60 x 130
250 x 90 x 130
250 x 90 x 130
14
Lenze · frequency inverter · 01/2020
i510 cabinet inverter
Connection to 400 V mains
Conformities
Approvals
Energy efficiency
Degree of protection
Power systems
Mains switching
Operation with
residual current
circuit breaker
Max. cable length for
EMC
Switching frequencies
Max. ambient
temperature
Max. output
frequency
Overload capacity
Rated power
Open type
TT, TN
IT
CE
EAC
RoHS 2
C
UL
US
Class IE2
IP20
2014/35/EU, 2014/30/EU
TR TC 004/2011, TP TC 020/2011
2011/65/EU
UL 61800-5-1, CSA 22.2 No. 274
EN 50598-2
EN 60529 (except in the wire range of terminals)
NEMA 250 (type 1 protection against accidental contact only)
Only in UL-approved systems
Voltage to earth: max. 300 V
Apply the measures described for IT systems!
3 x within one minute possible
Up to 4 kW 30 mA
Category C2
Category C3
20 m (≤0.37 kW max. 15 m)
35 m (≤0.37 kW max. 15 m)
2, 4, 8, 16 kHz. The rated output currents apply at 45 °C and
switching frequencies of 2 and 4 kHz, and at 40 °C and switching frequencies of 8 and 16 kHz
55 °C (derating of 2.5 %/°C above 45 °C)
0 Hz ... 599 Hz
200 % for 3s; 150 % for 60s
Mains voltageRated output
Weight
rangecurrent
[kW][V][A][kg]
3-phase inverter with integrated RFI filter
0.37
1.30.75
0.551.80.95
0.752.40.95
1.13.21.35
1.53.91.35
3/PE AC
2.25.61.35
340 V ... 528 V
45 Hz ... 65 Hz
37.31.35
49.51.35
5.5132.3
7.516.53.7
1123.53.7
3-phase mains connection 400 V - Light Duty with integrated RFI filter
4
8.81.35
5.511.91.35
3/PE AC
7.515.62.3
340 V ... 528 V
45 Hz ... 65 Hz
11233.7
1528.23.7
Dimensions
(h x w x d)
[mm]
155 x 60 x 130
180 x 60 x 130
180 x 60 x 130
250 x 60 x 130
250 x 60 x 130
250 x 60 x 130
250 x 60 x 130
250 x 60 x 130
250 x 90 x 130
276 x 120 x 130
276 x 120 x 130
250 x 60 x 130
250 x 60 x 130
250 x 90 x 130
276 x 120 x 130
276 x 120 x 130
i510-C0.37/400-3
i510-C0.55/400-3
i510-C0.75/400-3
i510-C1.1/400-3
i510-C1.5/400-3
i510-C2.2/400-3
i510-C3.0/400-3
i510-C4.0/400-3
i510-C5.5/400-3
i510-C7.5/400-3
i510-C11/400-3
i510-C3.0/400-3
i510-C4.0/400-3
i510-C5.5/400-3
i510-C7.5/400-3
i510-C11/400-3
Mains choke is generally prescribed for Light Duty with 15 kW.
Lenze · frequency inverter · 01/2020
15
i550 cabinet inverter
Connection to 120 V mains and 230 V mains
Conformities
Approvals
Energy efficiency
Degree of protection
Power systems
Mains switching
Operation with
residual current
circuit breaker
Max. cable length for
EMC
Switching frequencies
Max. ambient
temperature
Max. output
frequency
Overload capacity
Rated power
[kW]
i550-C0.25/120-1
i550-C0.37/120-1
i550-C0.75/120-1
i550-C1.1/120-1
i550-C0.25/230-1
i550-C0.37/230-1
i550-C0.55/230-1
i550-C0.75/230-1
i550-C1.1/230-1
i550-C1.5/230-1
i550-C2.2/230-1
i550-C0.25/230-2
i550-C0.37/230-2
i550-C0.55/230-2
i550-C0.75/230-2
i550-C1.1/230-2
i550-C1.5/230-2
i550-C2.2/230-2
i550-C0.25/230-2
i550-C0.37/230-2
i550-C0.55/230-2
i550-C0.75/230-2
i550-C1.1/230-2
i550-C1.5/230-2
i550-C2.2/230-2
i550-C4.0/230-3
i550-C5.5/230-3
0.25
0.37
0.75
1.1
0.25
0.37
0.55
0.75
1.1
1.5
2.2
0.25
0.37
0.55
0.75
1.1
1.5
2.2
0.25
0.37
0.55
0.75
1.1
1.5
2.2
4
5.5
Open type
TT, TN
IT
CE
EAC
RoHS 2
CULUS
Class IE2
IP20
2014/35/EU, 2014/30/EU
TR TC 004/2011, TP TC 020/2011
2011/65/EU
UL 61800-5-1, CSA 22.2 No. 274
EN 50598-2
EN 60529 (except in the wire range of terminals)
NEMA 250 (type 1 protection against accidental contact only)
Only in UL-approved systems
Voltage to earth: max. 300 V
Apply the measures described for IT systems!
3 x within one minute possible
up to 2.2 kW 30 mA, above this 300 mA
Category C2
Category C3
20 m (≤0.37 kW max. 15 m)
≥35 m (≤0.37 kW max. 15 m)
2, 4, 8, 16 kHz. The rated output currents apply at 45 °C and
switching frequencies of 2 and 4 kHz, and at 40 °C and switching frequencies of 8 and 16 kHz
55 °C (derating of 2.5 %/°C above 45 °C)
0 Hz ... 599 Hz
200 % for 3s; 150 % for 60s
Mains voltageRated output
Weight
rangecurrent
[V][A][kg]
1-phase mains connection 120 V without integrated RFI filter
1.71
1/N/PE AC
2.41
90 V ... 132 V
4.21.35
45 Hz ... 65 Hz
61.35
1-phase mains connection 230/240 V with integrated RFI filter
1.70.8
2.40.8
3.21
1/N/PE AC
4.21
170 V ... 264 V
45 Hz ... 65 Hz
61.35
71.35
9.61.35
1-phase mains connection 230/240 V without integrated RFI filter
1.70.8
2.40.8
3.21
1/N/PE A
4.21
170 V ... 264 V
45 Hz ... 65 Hz
61.35
71.35
9.61.35
3-phase mains connection 230/240 V without integrated RFI filter
1.70.8
2.40.8
3.21
4.21
3/PE AC
61.35
170 V ... 264 V
45 Hz ... 65 Hz
71.35
9.61.35
16.52.1
232.1
Dimensions
(h x w x d)
[mm]
180 x 60 x 130
180 x 60 x 130
250 x 60 x 130
250 x 60 x 130
155 x 60 x 130
155 x 60 x 130
180 x 60 x 130
180 x 60 x 130
250 x 60 x 130
250 x 60 x 130
250 x 60 x 130
155 x 60 x 130
155 x 60 x 130
180 x 60 x 130
180 x 60 x 130
250 x 60 x 130
250 x 60 x 130
250 x 60 x 130
155 x 60 x 130
155 x 60 x 130
180 x 60 x 130
180 x 60 x 130
250 x 60 x 130
250 x 60 x 130
250 x 60 x 130
250 x 90 x 130
250 x 90 x 130
16
Lenze · frequency inverter · 01/2020
i550 cabinet inverter
Connection to 400 V mains
Conformities
Approvals
Energy efficiency
Degree of protection
Power systems
Mains switching
Operation with
residual current
circuit breaker
Max. cable length for
EMC
Switching frequencies
Max ambient
temperature
Max. output
frequency
Overload capacity
Rated power
Open type
TT, TN
IT
CE
EAC
RoHS 2
CULUS
Class IE2
IP20
2014/35/EU, 2014/30/EU
TR TC 004/2011, TP TC 020/2011
2011/65/EU
UL 61800-5-1, CSA 22.2 No. 274
EN 50598-2
EN 60529 (except in the wire range of terminals)
NEMA 250 (type 1 protection against accidental contact only)
Only in UL-approved systems
Voltage to earth: max. 300 V
Apply the measures described for IT systems!
3 x within one minute possible
Up to 4 kW 30 mA
Category C2
Category C3
20 m (≤0.37 kW max. 15 m)
35 m (≤0.37 kW max. 15 m)
2, 4, 8, 16 kHz. The rated output currents apply at 45 °C and
switching frequencies of 2 and 4 kHz, and at 40 °C and switching frequencies of 8 and 16 kHz
55 °C (derating of 2.5 %/°C above 45 °C)
0 Hz ... 599 Hz
200 % for 3s; Heavy Duty: 150 % for 60s; Light Duty: 120 % for 60s
Mains voltageRated output
Weight
rangecurrent
[kW][V][A][kg]
3-phase mains connection 400 V – Heavy Duty with integrated RFI filter
0.37
1.30.8
0.551.81
0.752.41
1.13.21.35
1.53.91.35
2.25.61.35
37.31.35
49.51.35
5.5132.3
7.516.53.7
3/PE AC
340 V ... 528 V
1123.53.7
45 Hz ... 65 Hz
153210.3
18.54010.3
224710.3
306117.2
377617.2
458917.2
5511024
7515024
9018035.6
11021235.6
3-phase mains connection 400 V - Light Duty with integrated RFI filter
4
8.81.35
5.511.91.35
7.515.62.3
11233.7
1528.23.7
18.538.410.3
224810.3
3/PE AC
3056.410.3
340 V ... 528 V
45 Hz ... 65 Hz
3773.217.2
4591.217.2
5510717.2
7513224
9018024
11021635.6
13225435.6
Dimensions
(h x w x d)
[mm]
155 x 60 x 130
180 x 60 x 130
180 x 60 x 130
250 x 60 x 130
250 x 60 x 130
250 x 60 x 130
250 x 60 x 130
250 x 60 x 130
250 x 90 x 130
276 x 120 x 130
276 x 120 x 130
347 x 204.5 x 222
347 x 204.5 x 222
347 x 204.5 x 222
450 x 250 x 230
450 x 250 x 230
450 x 250 x 230
536 x 250 x 265
536 x 250 x 265
685 x 258 x 304
685 x 258 x 304
250 x 60 x 130
250 x 60 x 130
250 x 90 x 130
276 x 120 x 130
276 x 120 x 130
347 x 204.5 x 222
347 x 204.5 x 222
347 x 204.5 x 222
450 x 250 x 230
450 x 250 x 230
450 x 250 x 230
536 x 250 x 265
536 x 250 x 265
685 x 258 x 304
685 x 258 x 304
i550-C0.37/400-3
i550-C0.55/400-3
i550-C0.75/400-3
i550-C1.1/400-3
i550-C1.5/400-3
i550-C2.2/400-3
i550-C3.0/400-3
i550-C4.0/400-3
i550-C5.5/400-3
i550-C7.5/400-3
i550-C11/400-3
i550-C15/400-3
i550-C18/400-3
i550-C22/400-3
i550-C30/400-3
i550-C.37/400-3
i550-C45/400-3
i550-C55/400-3
i550-C75/400-3
i550-C90/400-3
i550-C110/400-3
i550-C3.0/400-3
i550-C4.0/400-3
i550-C5.5/400-3
i550-C7.5/400-3
i550-C11/400-3
i550-C15/400-3
i550-C18/400-3
i550-C22/400-3
i550-C30/400-3
i550-C37/400-3
i550-C45/400-3
i550-C55/400-3
i550-C75/400-3
i550-C90/400-3
i550-C110/400-3
Mains choke is generally prescribed from 22 kW (for Light Duty from 15 kW).
Lenze · frequency inverter · 01/2020
17
i550 protec inverter
Connection to 120 V mains and 230 V mains with IP66 degree of protection
ConformitiesCE
EAC
RoHS 2
UL
Class IE2
IP31
IP66
NEMA 250
NEMA 250
3M3 (for IP66)
3C2 (for IP66)
TN
2014/35/EU, 2014/30/EU
TP TC 004/2011, TP TC 020/2011
2011/65/EU
UL 61800-5-1, CSA 22.2 No. 274
EN 50598-2
EN 60529 (not in the wire range of terminals)
EN 60034-5
Type 1 (only protection against accidental contact)
Type 4X
EC 60721-3-3 (for mechanical, active substances)
EC 60721-3-3 (for chemical, active substances)
Voltage to earth: max. 300 V
3 x within one minute possible
Up to 11 kW 30 mA
Category:
C2 category C3
20 m (≤ 0.37 kW max. 15 m, 8 m for 1ph/230 V)
35 m (≤ 0.37 kW max. 15 m)
2, 4, 8, 12, 16 kHz. The rated output currents apply at 45 °C and
switching frequencies of 2 and 4 kHz, and at 40 °C and switching frequencies of 8, 12 and 16 kHz
55 °C (derating of 2.5 %/°C above 45 °C)
0 Hz ... 599 Hz
200 % for 3s; Heavy Duty: 150 % for 60s; Light Duty: 120 % for 60s (IP31 devices)
Rated power
Mains voltage Rated output Degree of
Weight
rangecurrentprotection
[kW][V][A][kg]
1-phase mains connection 120 V without integrated RFI filter
0.37
2.4IP661.8
1/N/PE AC
0.75
90 V … 132 V
4.2IP662.7
45 Hz … 65 Hz
1.16IP662.7
1-phase mains connection 230/240 V - Heavy Duty with integrated RFI filter
0.37
2.4IP661.7
0.553.2IP661.7
1/N/PE AC
0.754.2IP661.7
170 V … 264 V
1.16IP662.6
45 Hz … 65 Hz
1.57IP662.6
2.29.6IP662.6
1-phase mains connection 230/240 V - Heavy Duty without integrated RFI filter
0.37
2.4IP661.7
0.553.2IP661.7
1/N/PE AC
0.754.2IP661.7
170 V … 264 V
1.16IP662.6
45 Hz … 65 Hz
1.57IP662.6
2.29.6IP662.6
3-phase mains connection 230/240 V - Heavy Duty without integrated RFI filter
0.37
2.4IP661.7
0.553.2IP661.7
0.754.2IP661.7
1.16IP662.6
1.57IP662.6
3/PE AC
2.29.6IP662.6
340 V … 528 V
45 Hz … 65 Hz
312IP664.8
416.5IP664.8
5.523IP664.8
7.529IP665
1142IP665
Dimensions
(h x w x d)
[mm]
190 x 140 x 117
205 x 140 x 140
205 x 140 x 140
190 x 140 x 117
190 x 140 x 117
190 x 140 x 117
205 x 140 x 140
205 x 140 x 140
205 x 140 x 140
190 x 140 x 117
190 x 140 x 117
190 x 140 x 117
205 x 140 x 140
205 x 140 x 140
205 x 140 x 140
190 x 140 x 117
190 x 140 x 117
190 x 140 x 117
205 x 140 x 140
205 x 140 x 140
205 x 140 x 140
250 x 180 x 170
250 x 180 x 170
250 x 180 x 170
290 x 180 x 170
290 x 180 x 170
Approvals
Energy efficiency
Degree of protection
Power systems
Mains switching
Operation with
residual current
circuit breaker
Max. cable length for
EMC
Switching frequencies
Max. ambient
temperature
Max. output
frequency
Overload capacity
i550-P0.37/120-1
i550-P0.75/120-1
i550-P1.1/120-1
i550-P0.37/230-2
i550-P0.55/230-2
i550-P0.75/230-2
i550-P1.1/230-2
i550-P1.5/230-2
i550-P2.2/230-2
i550-P0.37/230-2
i550-P0.55/230-2
i550-P0.75/230-2
i550-P1.1/230-2
i550-P1.5/230-2
i550-P2.2/230-2
i550-P0.37/230-2
i550-P0.55/230-2
i550-P0.75/230-2
i550-P1.1/230-2
i550-P1.5/230-2
i550-P2.2/230-2
i550-P3.0/230-3
i550-P4.0/230-3
i550-P5.5/230-3
i550-P7.5/230-3
i550-P11/230-3
18
Lenze · frequency inverter · 01/2020
i550 protec inverter
Connection to 400 V mains with IP66 degree of protection
ConformitiesCE
EAC
RoHS 2
UL
Class IE2
IP31
IP66
NEMA 250
NEMA 250
3M3 (for IP66)
3C2 (for IP66)
TN
2014/35/EU, 2014/30/EU
TP TC 004/2011, TP TC 020/2011
2011/65/EU
UL 61800-5-1, CSA 22.2 No. 274
EN 50598-2
EN 60529 (not in the wire range of terminals)
EN 60034-5
Type 1 (only protection against accidental contact)
Type 4X
EC 60721-3-3 (for mechanical, active substances)
EC 60721-3-3 (for chemical, active substances)
Voltage to earth: max. 300 V
3 x within one minute possible
Up to 11 kW 30 mA
Category:
C2 category C3
20 m (≤ 0.37 kW max. 15 m)
35 m (≤ 0.37 kW max. 15 m)
2, 4, 8, 12, 16 kHz. The rated output currents apply at 45 °C and
switching frequencies of 2 and 4 kHz, and at 40 °C and switching frequencies of 8, 12 and 16 kHz
55 °C (derating of 2.5 %/°C above 45 °C)
0 Hz ... 599 Hz
200 % for 3s; Heavy Duty: 150 % for 60s; Light Duty: 120 % for 60s (IP31 devices)
Rated power
Mains voltage Rated output Degree of
rangecurrentprotection
[kW][V][A]
3-phase mains connection 400 V – Heavy Duty with integrated RFI filter
0.37
1.3IP66
0.551.8IP66
0.752.4IP66
1.13.2IP66
1.53.9IP66
3/PE AC
2.25.6IP66
340 V … 528 V
45 Hz … 65 Hz
37.3IP66
49.5IP66
5.513IP66
7.516.5IP66
1123.5IP66
Weight
[kg]
1.8
1.8
1.8
2.7
2.7
2.7
4.9
4.9
4.9
5.1
5.1
Dimensions
(h x w x d)
[mm]
190 x 140 x 117
190 x 140 x 117
190 x 140 x 117
205 x 140 x 140
205 x 140 x 140
205 x 140 x 140
250 x 180 x 170
250 x 180 x 170
250 x 180 x 170
290 x 180 x 170
290 x 180 x 170
Approvals
Energy efficiency
Degree of protection
Power systems
Mains switching
Operation with
residual current
circuit breaker
Max. cable length for
EMC
Switching frequencies
Max. ambient
temperature
Max. output
frequency
Overload capacity
i550-P0.37/400-3
i550-P0.55/400-3
i550-P0.75/400-3
i550-P1.1/400-3
i550-P1.5/400-3
i550-P2.2/400-3
i550-P3.0/400-3
i550-P4.0/400-3
i550-P5.5/400-3
i550-P7.5/400-3
i550-P11/400-3
Lenze · frequency inverter · 01/2020
19
8400 motec inverter
Connection to 400 V mains
ConformitiesCE
EAC
RoHS 2
UL
IP65
NEMA 250
NEMA 250
TN
2014/35/EU, 2014/30/EU
TP TC 004/2011, TP TC 020/2011
2011/65/EU
UL 508C, CSA 22.2 No. 274
EN 60529
Frame Unit service switch with protective function: IP64
Frame Unit service switch: IP54
Frame Unit service switch with control elements: IP54
Type 1 (only protection against accidental contact)
Type x (only indoor), wall mounting 0.37 kW ... 3 kW type 12
Voltage to earth: max. 300 V
3 x within one minute possible
30 mA, type B, in case of motor mounting or wall mounting with Lenze system cable < 3 m
300 mA, type B, in case of wall mounting with Lenze system cable > 3 m or
in case of motor mounting, 4.0 ... 7.5 kW, f
ch
= 4 kHz
< 20 m in case of wall mounting with Lenze system cable, f
ch
<= 4 kHz
< 10 m in case of wall mounting with Lenze system cable, f
ch
<= 8 kHz
4, 8, 16 kHz. The rated output currents listed below apply at 45 °C and a
switching frequency of 4 kHz, and at 40 °C and switching frequencies of 8 and 16 kHz
55 °C (derating of 2.5 %/°C above 45 °C)
0 Hz ... 599 Hz
200 % for 3s; 150 % for 60s
Rated power
Mains voltageRated output Degree of protec-Dimensions
Weight
rangecurrenttion(h x w x d)
[kW][V][A][kg][mm]
3-phase mains connection 400 V – Heavy Duty with integrated RFI filter
0.37
1.3IP54
0.551.8IP54
0.752.4IP54
1.13.2IP54
3/PE AC
1.53.9IP54
Varies depending on motor or wall
340 V ... 528 V
mounting and accessories
2.25.6IP54
45 Hz ... 65 Hz
37.3IP54
49.5IP54
5.513IP54
7.516.5IP54
Approvals
Degree of protection
Power systems
Mains switching
Operation with
residual current
circuit breaker
Max. cable length
for EMC
Switching
frequencies
Max. ambient
temperature
Max. output
frequency
Overload capacity
Category C2
E84DGDVB37142PS
E84DGDVB55142PS
E84DGDVB75142PS
E84DGDVB11242PS
E84DGDVB15242PS
E84DGDVB22242PS
E84DGDVB30242PS
E84DGDVB40242PS
E84DGDVB55242PS
E84DGDVB75242PS
20
Lenze · frequency inverter · 01/2020
Product extensions
Diagnostics and operation of the i5x0 cabinet
For diagnostics and parameterization, the keypad, the Lenze SMART Keypad app (iOS and Android) or the EASY Starter can be
used.
InverterExternal keypadKeypadWLANUSB
i550-Cxxx/120-1
i5x0-Cxxx/230-1
i5x0-Cxxx/230-2
i550-Cxxx/230-3
i5x0-Cxxx/400-3
I5MADR0000000S
3 m cable
I5MADR0000001S
5 m cable
I5MADR0000002S
I5MADK0000000SI5MADW0000000S
I5MADU0000000S
3 m cable
EWL0085/S
5 m cable
EWL0086/S
Functional safety for i5x0 cabinet
The safety function STO can also be ordered at a later date and retrofitted.
InverterSafety function STO (Safe Torque Off)
i550-Cxxx/120-1
i550-Cxxx/230-1
i550-Cxxx/230-2
i550-Cxxx/230-3
i550-Cxxx/400-3
I5MASAV000000S
Lenze · frequency inverter · 01/2020
21
Accessories
Mains choke for i5x0 cabinet
i550 cabinet: generally prescribed from 22 kW (for Light Duty from 15 kW)
i500 protec: integrated in the device if required (>= 30 kW)
•
•
•
•
Mains chokes reduce the effects of the inverter on the supplying mains by smoothing the harmonics.
The effective mains current is reduced which saves energy.
Mains chokes can be used without restrictions in conjunction with RFI filters.
Please note that the use of a mains choke reduces the mains voltage at the input of the inverter by 4 % (typical voltage drop
across the mains choke).
Mains choke
Degree
of pro-
tection
Dimensions
(h x w x d)
mm
Operation at 1 x 120 V
0.25
0.37
0.75
1.10
0.25
0.37
0.55
0.75
1.10
1.50
2.20
0.25
0.37
0.55
0.75
1.10
1.50
2.20
4.0
5.5
ELN1-0500H009
ELN1-0500H009
ELN1-0250H018
ELN1-0250H018
ELN1-0900H005
ELN1-0900H005
ELN1-0500H009
ELN1-0500H009
ELN1-0250H018
ELN1-0250H018
ELN1-0250H018
EZAELN3002B153
EZAELN3004B742
EZAELN3004B742
EZAELN3006B492
EZAELN3006B492
EZAELN3008B372
EZAELN3010B292
EZAELN3016B182
EZAELN3025B122
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
75 x 66 x 82
75 x 66 x 82
96 x 96 x 90
96 x 96 x 90
75 x 66 x 82
75 x 66 x 82
75 x 66 x 82
75 x 66 x 82
96 x 96 x 90
96 x 96 x 90
96 x 96 x 90
56 x 77 x 100
60 x 95 x 115
60 x 95 x 115
69 x 95 x 120
69 x 95 x 120
85 x 120 x 140
85 x 120 x 140
95 x 120 x 140
110 x 155 x 170
0.37
0.55
0.75
1.10
1.50
2.20
3.0
4.0
5.50
7.50
11
15
18.5
22
30
37
45
55
75
90
110
132
Rated power
kW
Operation at 3 x 400 V
EZAELN3002B203
EZAELN3002B153
EZAELN3004B742
EZAELN3004B742
EZAELN3004B742
EZAELN3006B492
EZAELN3008B372
EZAELN3010B292
EZAELN3016B182
EZAELN3016B182
EZAELN3025B122
EZAELN3030B981
EZAELN3040B741
EZAELN3045B651
EZAELN3063B471
EZAELN3080B371
EZAELN3080B371
EZAELN3100B301
EZAELN3160B191
EZAELN3180B171
EZAELN3200B151
EZAELN3250B121
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
56 x 77 x 100
56 x 77 x 100
60 x 95 x 115
60 x 95 x 115
60 x 95 x 115
69 x 95 x 120
85 x 120 x 140
85 x 120 x 140
95 x 120 x 140
95 x 120 x 140
110 x 155 x 170
110 x 155 x 170
112 x 185 x 200
112 x 185 x 200
122 x 185 x 210
125 x 210 x 240
125 x 210 x 240
139 x 267 x 205
149 x 291 x 215
164 x 316 x 235
144 x 352 x 265
207 x 352 x 260
Mains choke
Degree
of pro-
tection
Dimensions
(h x w x d)
mm
Rated power
kW
Operation at 1 x 230 V
Operation at 1 x 230 V or at 3 x 230 V
Operation at 3 x 230 V
22
Lenze · frequency inverter · 01/2020
Filter Short Distance for i5x0 cabinet
Filter type: RFI filter
• C1 to 25 m
• C2 to 50 m
• Reduced leakage current, operation on 30-mA residual current circuit breaker possible
Filter Long Distance for i5x0 cabinet
Filter type up to 15 kW: RFI filter
Filter type from 22 kW: Mains filter (combination of RFI filter and mains choke)
• C1 to 50 m
• C2 to 100 m
• Operation with 300 mA residual current circuit breaker
Short Distance
Rated powerRFI filter
Degree
of pro-
Dimensions
tection
(h x w x d)
kWmm
Operation at 1 x 230 V
0.25I0FAE175B100S0000SIP20276 x 60 x 50
0.37I0FAE175B100S0000SIP20276 x 60 x 50
0.55I0FAE175B100S0000SIP20276 x 60 x 50
0.75I0FAE175B100S0000SIP20276 x 60 x 50
1.10I0FAE222B100S0000SIP20346 x 60 x 50
1.50I0FAE222B100S0000SIP20346 x 60 x 50
2.20I0FAE222B100S0000SIP20346 x 60 x 50
Operation at 3 x 400 V
0.37I0FAE175F100S0000SIP20276 x 60 x 50
0.55I0FAE175F100S0000SIP20276 x 60 x 50
0.75I0FAE175F100S0000SIP20276 x 60 x 50
1.10I0FAE222F100S0000SIP20346 x 60 x 50
1.50I0FAE222F100S0000SIP20346 x 60 x 50
2.20I0FAE222F100S0000SIP20346 x 60 x 50
3.0I0FAE255F100S0001SIP20346 x 90 x 60
4.0I0FAE255F100S0001SIP20346 x 90 x 60
5.50I0FAE255F100S0001SIP20346 x 90 x 60
7.50I0FAE311F100S0000SIP20371 x 120 x 60
11I0FAE311F100S0000SIP20371 x 120 x 60
15--
18.5--
22--
30--
37--
45--
55--
75--
90--
110--
132--
Lenze · frequency inverter · 01/2020
Long Distance
Rated powerRFI filter
Degree
of pro-
Dimensions
tection
(h x w x d)
kWmm
Operation at 1 x 230 V
0.25I0FAE175B100D0000SIP20276 x 60 x 50
0.37I0FAE175B100D0000SIP20276 x 60 x 50
0.55I0FAE175B100D0000SIP20276 x 60 x 50
0.75I0FAE175B100D0000SIP20276 x 60 x 50
1.10I0FAE222B100D0000SIP20346 x 60 x 50
1.50I0FAE222B100D0000SIP20346 x 60 x 50
2.20I0FAE222B100D0000SIP20346 x 60 x 50
Operation at 3 x 400 V
0.37I0FAE175F100D0000SIP20276 x 60 x 50
0.55I0FAE175F100D0000SIP20276 x 60 x 50
0.75I0FAE175F100D0000SIP20276 x 60 x 50
1.10I0FAE222F100D0000SIP20346 x 60 x 50
1.50I0FAE222F100D0000SIP20346 x 60 x 50
2.20I0FAE222F100D0000SIP20346 x 60 x 50
3.0I0FAE240F100D0000SIP20346 x 60 x 50
4.0 heavyI0FAE240F100D0000SIP20346 x 60 x 50
4.0 lightI0FAE255F100D0001SIP20346 x 90 x 60
5.50I0FAE255F100D0001SIP20346 x 90 x 60
7.50I0FAE311F100D0000SIP20371 x 120 x 60
11I0FAE311F100D0000SIP20371 x 120 x 60
15I0FAE318F100D0000SIP20436 x 205 x 90
18.5I0FAE318F100D0000SIP20436 x 205 x 90
22 heavyI0FAE322F100D0000SIP20436 x 205 x 90
22 lightI0FAE330F100D0000SIP20590 x 250 x 105
30I0FAE330F100D0000SIP20590 x 250 x 105
37I0FAE337F100D0000SIP20590 x 250 x 105
45I0FAE345F100D0001SIP20590 x 250 x 105
55I0FAE355F100D0001SIP20700 x 250 x 105
75I0FAE375F100D0001SIP20700 x 250 x 105
90I0FAE411F100D0001SIP20855 x 250 x 130
110I0FAE411F100D0001SIP20855 x 250 x 130
132I0FAE411F100D0001SIP20855 x 250 x 130
23
Brake resistor for i550 cabinet
• To decelerate greater moments of inertia or with a longer operation in generator mode, an external brake resistor is
required.
• The brake resistor absorbs the brake energy produced in generator mode and converts it into heat.
Rated power
kW
0.25
0.37
0.75
1.10
0.25
0.37
0.55
0.75
1.10
1.50
2.20
0.25
0.37
0.55
0.75
1.10
1.50
2.20
ERBM180R050W
ERBM180R050W
ERBP047R200W
ERBP047R200W
ERBM180R050W
ERBM180R050W
ERBM100R100W
ERBM100R100W
ERBP033R200W
ERBP033R200W
ERBP033R200W
ERBM180R050W
ERBM180R050W
ERBM100R100W
ERBM100R100W
ERBP033R200W
ERBP033R200W
ERBP033R200W
Brake resistorRated power
W
Operation at 1 x 120 V
50
50
200
200
Operation at 1 x 230 V
50
50
100
100
200
200
200
Operation at 1 x 230 V or at 3 x 230 V
50
50
100
100
200
200
200
IP54
IP54
IP54
IP54
IP21
IP21
IP21
175 x 21 x 40
175 x 21 x 40
240 x 80 x 95
240 x 80 x 95
240 x 41 x 122
240 x 41 x 122
240 x 41 x 122
IP54
IP54
IP54
IP54
IP21
IP21
IP21
175 x 21 x 40
175 x 21 x 40
240 x 80 x 95
240 x 80 x 95
240 x 41 x 122
240 x 41 x 122
240 x 41 x 122
IP54
IP54
IP21
IP21
175 x 21 x 40
175 x 21 x 40
320 x 41 x 122
320 x 41 x 122
Degree of protection
Dimensions
(h x w x d)
mm
24
Lenze · frequency inverter · 01/2020
Rated power
kW
4.0
5.5
0.37
0.55
0.75
1.10
1.50
2.20
3.0
4.0
5.50
7.50
11
15
18.5
22
30
37
45
55
75
90
110
132
Brake resistorRated power
W
Operation at 3 x 230 V
Degree of protection
Dimensions
(h x w x d)
mm
ERBS015R800W
ERBS015R800W
ERBM390R100W
ERBM390R100W
ERBM390R100W
ERBP180R200W
ERBP180R200W
ERBP180R200W
ERBP082R200W
ERBP047R200W
ERBP047R200W
ERBP027R200W
ERBP027R200W
ERBS018R800W
ERBS015R800W
ERBS015R800W
ERBG075D01K9
ERBG075D01K9
ERBG075D01K9
ERBG005R02K6
ERBG005R02K6
ERBG028D04K1
ERBG028D04K1
ERBG028D04K1
800
800
Operation at 3 x 400 V
100
100
100
200
200
200
200
200
200
200
200
800
800
800
1900
1900
1900
2600
2600
4100
4100
4100
IP66
IP66
IP54
IP54
IP54
IP21
IP21
IP21
IP21
IP21
IP21
IP21
IP21
IP66
IP66
IP66
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
710 x 110 x 105
710 x 110 x 105
235 x 21 x 40
235 x 21 x 40
235 x 21 x 40
240 x 41 x 122
240 x 41 x 122
240 x 41 x 122
320 x 41 x 122
320 x 41 x 122
320 x 41 x 122
320 x 41 x 122
320 x 41 x 122
710 x 110 x 105
710 x 110 x 105
710 x 110 x 105
486 x 236 x 302
486 x 236 x 302
486 x 236 x 302
486 x 326 x 302
486 x 326 x 302
486 x 426 x 302
486 x 426 x 302
486 x 426 x 302
Lenze · frequency inverter · 01/2020
25
Brake resistor for i550 protec
• To decelerate greater moments of inertia or with a longer operation in generator mode, an external brake resistor is
required.
• The brake resistor absorbs the brake energy produced in generator mode and converts it into heat.
Rated power
kW
0.37
0.75
1.10
0.37
0.55
0.75
1.10
1.50
2.20
0.37
0.55
0.75
1.10
1.50
2.20
ERBS180R350W
ERBS100R625W
ERBS100R625W
ERBS100R625W
ERBS100R625W
ERBS100R625W
ERBS039R01K6
ERBS039R01K6
ERBS039R01K6
ERBS470R150W
ERBS470R150W
ERBS470R150W
ERBS180R350W
ERBS180R350W
ERBS180R350W
Brake resistorRated power
W
Operation at 1 x 230 V
350
625
625
Operation at 1 x 230 V or at 3 x 230 V
625
625
625
1600
1600
1600
Operation at 3 x 400 V
150
150
150
350
350
350
IP66
IP66
IP66
IP66
IP66
IP66
222 x 124 x 122
222 x 124 x 122
222 x 124 x 122
382 x 124 x 122
382 x 124 x 122
382 x 124 x 122
IP66
IP66
IP66
IP66
IP66
IP66
566 x 124 x 122
566 x 124 x 122
566 x 124 x 122
748 x 200 x 122
748 x 200 x 122
748 x 200 x 122
IP66
IP66
IP66
382 x 124 x 122
566 x 124 x 122
566 x 124 x 122
Degree of protection
Dimensions
(h x w x d)
mm
26
Lenze · frequency inverter · 01/2020
Motor shield plate for i5x0 cabinet
Rated power
kW
0.25 ... 1.1 kW
0.25 ... 2.2 kW
4.0 ... 5.5 kW
0.37 ... 4.0 kW
5.5 kW
7.5 ... 11 kW
15 ... 22 kW
30 ... 75 kW
Shield mounting
Multiple
Operation at 1 x 120 V
EZAMBHXM018/M
EZAMBHXM018/M
EZAMBHXM015/M
EZAMBHXM018/M
EZAMBHXM015/M
EZAMBHXM016/M
EZAMBHXM004/M
EZAMBHXM005/M
5
Operation at 1 x 230 V
5
Operation at 3 x 230 V
5
Operation at 3 x 400 V
5
5
5
10
10
EZAMBHXM018/S
EZAMBHXM015/S
EZAMBHXM016/S
-
-
1
1
1
-
-
EZAMBHXM015/S1
EZAMBHXM018/S1
EZAMBHXM018/S1
Packaging unitShield mounting
Simple
Packaging unit
Contents: Motor shield plate, fixing clip, terminal clamp.
Exception: EZAMBHXM004 and EZAMBHXM005 only include terminal clamps as the shield plate comes supplied with the device
Accessory sets for i5x0 protec
The bottom of the housing of the i510 protec and i550 protec inverters provides openings for connections to the mains, the
motor and the control connections. To easily implement these connections in IP66, various connection sets are available.
Connection set
i550 protec screw connection set
0.37 ... 2.2 kW
i550 protec screw connection set
3 ... 11 kW
I550 protec screw connection set
for Ethernet-based networks
Pressure compensation screw connection M12
QUICKON connection set
Switch/potentiometer set
Contents
3x M20 und 2x M12
cable glands
1x M32, 2x M20 and 2x M12
cable glands
Separable rubber bushing and
screw connection for 2x RJ45 connector
M12 screw connection
with integrated membrane
QUICKON panel feed-through QDP
with connection cable
3-point switch
1x 10 kΩ potentiometer
Packaging unit
1
1
1
5
1
1
EZAMBHXX022
EZAMBHXX023
EZAMBHXX025
EZAMBHXX026
EZAMBHXX027
EZAMBHXX028
Lenze · frequency inverter · 01/2020
27
© 02/2020 · 13592415 · 1.0 ·