2024年5月10日发(作者:)

SUN M4000更换内存实例

一、错误日志

MEMB#0 Status:Normal; Ver:0101h; Serial:BF0843MAK5 ;

+ FRU-Part-Number:CF00541-0545 06 /541-0545-06 ;

MEM#0A Status:Normal;

+ Code:ce0001M3 93T5750EZA-CE6 4145-480d2d38;

+ Type:2B; Size:2 GB;

MEM#0B Status:Normal;

+ Code:ce0001M3 93T5750EZA-CE6 4145-480d2d0f;

+ Type:2B; Size:2 GB;

MEM#1A Status:Normal;

+ Code:ce0001M3 93T5750EZA-CE6 4145-480d2dff;

+ Type:2B; Size:2 GB;

MEM#1B Status:Normal;

+ Code:ce0001M3 93T5750EZA-CE6 4145-480d2d6d;

+ Type:2B; Size:2 GB;

* MEM#2A Status:Degraded;

+ Code:ce0001M3 93T5750EZA-CE6 4145-480d2de8;

+ Type:2B; Size:2 GB;

定位错误内存条:MEMB#0: MEM#2A:第一个内存板,(

图是

M5000

机器

)

1 Memory board (MEMB#0)

2 Memory board (MEMB#1)

3 Memory board (MEMB#2)

4 Memory board (MEMB#3)

5 Memory board (MEMB#4)

6 Memory board (MEMB#5)

7 Memory board (MEMB#6)

8 Memory board (MEMB#7)

1 MEM#2A, Memory Slot (Group A)

2 MEM#2B, Memory Slot (Group B)

3 MEM#3A, Memory Slot (Group A)

4 MEM#3B, Memory Slot (Group B)

5 MEM#1B, Memory Slot (Group B)

6 MEM#1A, Memory Slot (Group A)

7 MEM#0B, Memory Slot (Group B)

8 MEM#0A, Memory Slot (Group A)

二、操作步骤:

1、再次查看报错信息,定位错误内存条。

XSCF> showhardconf

2、关闭主机

shutdown -g0 -y

XSCF> poweroff -a 确认电源已关闭 或 XSCF>poweroff -d 00 关闭电源

记录线缆位置

3、更换内存

找到对应的号替换

4、查看更换后状态

XSCF>poweron -d 00 //打开电源 或poweron -a

XSCF> showhardconf

备注:进入XSCF

串口线接上后要求登录:default

按提示把机箱前的钥匙转到维护标记,回车

提示把钥匙转向锁定的标记 5秒后回车进入XSCF>

从XSCF进入系统console -d 0

从系统返回XSCF 按#.

三、更换后的日志

XSCF> showhardconf

SPARC Enterprise M4000;

+ Serial:BEF08474C3; Operator_Panel_Switch:Locked;

+ Power_Supply_System:Single; SCF-ID:XSCF#0;

+ System_Power:Off; System_Phase:Cabinet Power Off;

Domain#0 Domain_Status:Powered Off;

MBU_A Status:Normal; Ver:0101h; Serial:BE08471F7F ;

+ FRU-Part-Number:CF00541-0893 06 /541-0893-06 ;

+ Memory_Size:32 GB;

CPUM#0-CHIP#0 Status:Normal; Ver:0401h; Serial:PP0842014G ;

+ FRU-Part-Number:CA06761-D202 D0 /375-3568-04 ;

+ Freq:2.400 GHz; Type:32;

+ Core:4; Strand:2;

CPUM#0-CHIP#1 Status:Normal; Ver:0401h; Serial:PP0842014G ;

+ FRU-Part-Number:CA06761-D202 D0 /375-3568-04 ;

+ Freq:2.400 GHz; Type:32;

+ Core:4; Strand:2;

MEMB#0 Status:Normal; Ver:0101h; Serial:BF0843MAK5 ;

+ FRU-Part-Number:CF00541-0545 06 /541-0545-06 ;

MEM#0A Status:Normal;

+ Code:ce0001M3 93T5750EZA-CE6 4145-480d2d38;

+ Type:2B; Size:2 GB;

MEM#0B Status:Normal;

+ Code:ce0001M3 93T5750EZA-CE6 4145-480d2d0f;

+ Type:2B; Size:2 GB;

MEM#1A Status:Normal;

+ Code:ce0001M3 93T5750EZA-CE6 4145-480d2dff;

+ Type:2B; Size:2 GB;

MEM#1B Status:Normal;

+ Code:ce0001M3 93T5750EZA-CE6 4145-480d2d6d;

+ Type:2B; Size:2 GB;

MEM#2A Status:Normal;

+ Code:2c000836HTF25672PY-667D10100-dc2ad981;

+ Type:2B; Size:2 GB;

MEM#2B Status:Normal;

+ Code:ce0001M3 93T5750EZA-CE6 4145-480d2e01;

+ Type:2B; Size:2 GB;

MEM#3A Status:Normal;

+ Code:ce0001M3 93T5750EZA-CE6 4145-480d2d66;

+ Type:2B; Size:2 GB;

MEM#3B Status:Normal;

+ Code:ce0001M3 93T5750EZA-CE6 4145-480d2dc1;

+ Type:2B; Size:2 GB;

MEMB#1 Status:Normal; Ver:0101h; Serial:BF0843MADF ;

+ FRU-Part-Number:CF00541-0545 06 /541-0545-06 ;

MEM#0A Status:Normal;

+ Code:ce0001M3 93T5750EZA-CE6 4145-480d2d0e;

+ Type:2B; Size:2 GB;

MEM#0B Status:Normal;

+ Code:ce0001M3 93T5750EZA-CE6 4145-480d2d37;

+ Type:2B; Size:2 GB;

MEM#1A Status:Normal;

+ Code:ce0001M3 93T5750EZA-CE6 4145-480d2d10;

+ Type:2B; Size:2 GB;

MEM#1B Status:Normal;

+ Code:ce0001M3 93T5750EZA-CE6 4145-480d2d07;

+ Type:2B; Size:2 GB;

MEM#2A Status:Normal;

+ Code:ce0001M3 93T5750EZA-CE6 4145-480d2dc3;

+ Type:2B; Size:2 GB;

MEM#2B Status:Normal;

+ Code:ce0001M3 93T5750EZA-CE6 4145-480d2d4e;

+ Type:2B; Size:2 GB;

MEM#3A Status:Normal;

+ Code:ce0001M3 93T5750EZA-CE6 4145-480d2d46;

+ Type:2B; Size:2 GB;

MEM#3B Status:Normal;

+ Code:ce0001M3 93T5750EZA-CE6 4145-480d2d20;

+ Type:2B; Size:2 GB;

DDC_A#0 Status:Normal;

DDC_A#1 Status:Normal;

DDC_B#0 Status:Normal;

IOU#0 Status:Normal; Ver:0101h; Serial:BF0843M8V6 ;

+ FRU-Part-Number:CF00541-2240 03 /541-2240-03 ;

DDC_A#0 Status:Normal;

DDCR Status:Normal;

DDC_B#0 Status:Normal;

XSCFU Status:Normal,Active; Ver:0101h; Serial:BF0842LU0X ;

+ FRU-Part-Number:CF00541-0481 04 /541-0481-04 ;

OPNL Status:Normal; Ver:0101h; Serial:BF0844MHP2 ;

+ FRU-Part-Number:CF00541-0850 06 /541-0850-06 ;

PSU#0 Status:Normal; Serial:1357FYG-0837AD00T5;

+ FRU-Part-Number:CF00300-2011 0202 /300-2011-02-02;

+ Power_Status:Off; AC:200 V;

PSU#1 Status:Normal; Serial:1357FYG-0837AD00TQ;

+ FRU-Part-Number:CF00300-2011 0202 /300-2011-02-02;

+ Power_Status:Off; AC:200 V;

FAN_A#0 Status:Normal;

FAN_A#1 Status:Normal;

FANBP_B Status:Normal; Ver:0201h; Serial:BF0843MDB8 ;

+ FRU-Part-Number:CF00541-0909 04 /541-0909-04 ;

FAN_B#0 Status:Normal;

FAN_B#1 Status:Normal;

XSCF>

XSCF> poweron

XSCF> poweron -d 00

DomainIDs to power on:00

Continue? [y|n] :y

00 :Powering on

gzcwapp2 console login: