Unconfigured(bad)硬盘上线办法43204-CIVS-HDD

Hard Drive in a CIVS-MSP shows up as

‘Unconfigured(bad)’

Jim Sullivan 05-06-2011

It?s possible a hard drive may show up as …unconfigured(bad)? within the raid configuration. This could be experienced when

replacing a drive that has failed, or simply show up because a single drive encountered errors and did not properly recover.

Below is a procedure I have captured to add the …unconfigured(bad)? drive back to the existing array.

List all drive info to identify slot:

Once slot 4 in enclosure 16 has been identified you can list single drive info:

Make the drive …Unconfigured(good)?:

Check the status of [16:4] to make sure it is …Unconfigured(good)?:

We will need to clear the …foreign conifig?:

Once 'Foreign' configuration is cleared, set drive as hotspare:

You will notice below by listing the info of the drive, it has automatically started to rebuild at this point.

The status of the rebuild can be checked:

If the drive fails to start rebuilding after being set as a hotspare, the rebuild process can be manually started.

Please note that this procedure will not recover a drive that has truly failed. If the drive can?t be added back to the array with this

procedure

the drive will need to be replaced.