2024年5月27日发(作者:)

ACOPOS贝加莱伺服出错代码表(全)

ACOPOS 出错代码表

1: 参数 ID 无效 Parameter ID invalid

2: 参数不可读 ( 变量不能在该时刻读取) Parameter can not be read (value is not

available at the moment)

3: 对只读参数写访问 Write access for a read only parameter

4: 对只写参数读访问 Read access for a write only parameter

5: 参数数值无效 Value of parameter is invalid

(REAL): 变量格式 Info(REAL): Value of Parameter

6: 参数数值无效 Value of parameter is invalid

(UDINT): 变量格式 Info(UDINT): Value of Parameter

7: 参数数值无效 Value of parameter is invalid

(DINT): 变量格式 Info(DINT): Value of Parameter

8: 数据块读访问已经初始化 Data block read access already initialized

9: 数据块写访问已经初始化 Data block write access already initialized

10: 数据块读访问未初始化 Data block read access not initialized

11: 数据块写访问未初始化 Data block write access not initialized

12: 数据块读访问仍激活 ( 读访问初始化不可能)

Data block write access still active (INIT for read access not possible)

13: 数据块写访问仍激活(写访问初始化不可能)

Data block read access still active (INIT for write access not possible)

14: 读响应超时 Timeout for Read Response

15: 写响应超时 Timeout for Write Response

16: 数据块数据段在读已经在最后 The Data segment at data block read is already

the last

17: 数据块数据段在写已经在最后 The Data segment at data block write is already

the last

18: 数据块数据段未在读在最后 The Data segment at data block read is not yet

the last

Info(UDINT): 数据块偏移 Data block offset

19: 数据段未在写数据块的最后

Info(UDINT): 数据块偏移 Data block offset

20: 数据块读后检验和无效 Checksum after data block read is invalid

21: 数据块写后检验和无效 Checksum after data block write is invalid

22: 参数 ID 在数据块中无效(读数据块) Parameter ID in data block is invalid

(data block read)

Info('PARID'): Parameter ID

23: 参数 ID 在数据块中无效(写数据块) Parameter ID in data block is invalid

(data block write)

Info('PARID'): Parameter ID

24: 在启动状态不允许下载系统模块 System module download not allowed in this

boot state

Info(UINT): Boot state

25: 只在下载后允许立即烧结系统模块 Burn system module only allowed

immediately after download

26: 在启动状态不允许改变启动状态请求 Requested change of boot state is not

allowed in this boot state

Info(UINT): Boot state

27: 启动操作系统不可能(操作系统不在FPROM 存储器中)

Start of operating system not possible (operating system is not on the FPROM)

28: 在此驱动状态不允许读参数 Read parameter not allowed in this drive state

Info(UINT): Drive state

29: 在此驱动状态

不允许写参数 Write parameter not allowed in this drive state

Info(UINT): Drive state

30: 因为硬件故障不能读参数 Read parameter not possible because of hardware

error

Info(UINT): Hardware error

31: 因为硬件故障不能写参数 Write parameter not possible because of hardware

error

Info(UINT): Hardware error

32: 命令参数无效 Command parameter is invalid

Info('PARID'): Parameter ID

40: 参数数值大于最大值 Value of parameter higher than maximum value

Info(REAL): Maximum value

41: 参数数值大于最大值 Value of parameter higher than maximum value

Info(UDINT): Maximum value

42: 参数数值大于最大值 Value of parameter higher than maximum value

Info(DINT): Maximum value

43: 参数1 数值大于最大值 Value of parameter1 higher than maximum value

Info(REAL): Maximum value

44: 参数1 数值大于最大值 Value of parameter1 higher than maximum value

Info(UDINT): Maximum value

45: 参数1 数值大于最大值 Value of parameter1 higher than maximum value

Info(DINT): Maximum value

46: 参数2 数值大于最大值 Value of parameter2 higher than maximum value

Info(REAL): Maximum value

47: 参数2 数值大于最大值 Value of parameter2 higher than maximum value

Info(UDINT): Maximum value

48: 参数2 数值大于最大值 Value of parameter2 higher than maximum value

Info(DINT): Maximum value

49: 参数3 数值大于最大值 Value of parameter3 higher than maximum value

Info(REAL): Maximum value

50: 参数3 数值大于最大值 Value of parameter3 higher than maximum value

Info(UDINT): Maximum value

51: 参数3 数值大于最大值 Value of parameter3 higher than maximum value

Info(DINT): Maximum value

52: 参数数值小于最小值 Value of parameter lower than minimum value

Info(REAL): Minimum value

53: 参数数值小于最小值 Value of parameter lower than minimum value

Info(UDINT): Minimum value

54: 参数数值小于最小值 Value of parameter lower than minimum value

Info(DINT): Minimum value

55: 参数1 数值小于最小值 Value of parameter1 lower than minimum value

Info(REAL): Minimum value

56: 参数1 数值小于最小值 Value of parameter1 lower than minimum value

Info(UDINT): Minimum value

57: 参数1 数值小于最小值 Value of parameter1 lower than minimum value

Info(DINT): Minimum value

58: 参数2 数值小于最小值 Value of parameter2 lower than minimum value

Info(REAL): Minimum value

59: 参数2 数值小于最小值 Value of parameter2 lower than minimum value

Info(UDINT): Minimum value

60: 参数2 数值小于最小值 Value of parameter2 lower than minimum value

Info(DINT): Minimum value

61: 参数3 数值小于最小值 Value of parameter3 lower than minimum value

Info(REAL): Minimum value

62: 参数

3 数值小于最小值 Value of parameter3 lower than minimum value

Info(UDINT): Minimum value

63: 参数3 数值小于最小值 Value of parameter3 lower than minimum value

Info(DINT): Minimum value

64: 硬件ID 在B&R 模块中无效(数据块写) Hardware ID in B&R module is

invalid (data block write)

Info(USINT): Hardware ID

65: 硬件版本在B&R 模块中无效(数据块写)

Hardware Version in B&R module is invalid (data block write)

Info(USINT): Hardware Revision

66: 硬件ID 的操作系统不兼容现在的总线网络

Hardware ID of operating system is incompatible to the existing network

Info(USINT): Hardware ID

1001: 数据先进先出溢出 Error FIFO overflow

1002: 参数超出有效范围 Parameter outside the valid range

1003: 在回路控制激活时不允许写参数 Writing parameter is not allowed during

loop control is active

1004: 激活信号控制网络超时 Timeout in network live sign control

1005: 在动作激活时不允许写参数 Writing parameter is not allowed during a

movement is active

1006: 用于触发事件(数字量输入+ 边沿)无效参数

Invalid parameter for trigger event (digital input + edge)

1007: 主站用于网络耦合未激活-一个主站已经发送

Master for network coupling deactivated - one master is already sending

1008: 主站用于网络耦合未激活-编码器错误 Master for network coupling

deactivated - Encoder error

1009: 内存分配错误 Error on memory allocation

1010: 先进先出功能块溢出 Function FIFO overflow

1011: 快停输入激活 Quickstop input active

1012: 循环网络通信切断 Breakdown of cyclic network communication

1013: 用于网络通信的站点不可行 Station is not available for network

communication

1014: AC112 命令接口占用 AC112 command interface is occupied

2001: 上载跟踪曲线数据不允许:记录激活 Upload of trace data not allowed:

Recording active

2002: 无跟踪曲线数据可上载 No trace data available for upload

2003: 跟踪曲线启动不允许:记录激活 Trace start not allowed: Recording active

2004: 跟踪曲线启动不允许:未定义跟踪数据Trace start not allowed: No trace test

data defined

2005: 无效的参数ID 用于跟踪测试数据 Invalid parameter ID for trace test data

Info('PARID'): Parameter ID

2006: 初始跟踪参数不允许:记录激活 Initialization of trace parameters not

allowed: Recording active

4002: 在仿真命令无效的动作代码 Invalid action code in simulation command

4004: 在控制器命令无效的动作代码 Invalid action code in controller command

4005: 使能控制器无效:驱动器错误 Switch controller on not possible: Drive in

error state

4007: 跟随误差超限停止 Lag error stop limit exceeded

Info(REAL): Current lag error

4008: 正限位开关到达 Positive limit switch r

eached

4009: 负限位开关到达 Negative limit switch reached

4010: 使能控制器无效:两限位关闭 Switch controller on not possible: Both limit

switches are closed

4011: 关闭控制器无效:运动激活 Switch controller off not possible: Movement

active

4012: 使能控制器无效:初始参数丢失或无效

Switch controller on not possible: Initial parameter missing or not valid

Info('PARID'): Parameter ID

4014: 双编码器控制:位置偏差超限停止 Two encoder control: Stop limit of

positions difference exceeded

Info(REAL): Current positions difference

5001: 目标位置大于正向软限位 Target position > positive SW limit

5002: 目标位置小于负向软限位 Target position < negative SW limit

5003: 正向软限位到达 Positive SW limit reached

5004: 负向软限位到达 Negative SW limit reached

5005: 运动启动不可能:位置控制器未激活 Start of movement not possible:

Position controller inactive

5006: 运动启动不可能:轴未寻参考位置 Start of movement not possible: Axis not

referenced

5010: 正向位置运动不可能:正向限位开关关闭

Move in pos. direction not possible: Pos. limit switch is closed

5011: 负向位置运动不可能:负向限位开关关闭

Move in neg. direction not possible: Neg. limit switch is closed

5012: 运动启动不可能:停止激活 Start of movement not possible: Stop ramp

active

5013: 打开循环设值模式不可能:运动激活

Switching on cyclic set value mode is not possible: Movement active

5014: 关闭循环设值模式不可能 Switching off cyclic set value mode is not

possible

5015: 运动启动不可能:正在寻参 Start of movement not possible: Homing

procedure active

5016: 写参数不允许:正在寻参 Write parameter not allowed: Homing procedure

active

5017: 寻参步骤模式不可能:位置控制器未激活

Homing procedure mode not possible: Position controller inactive

5018: 寻参步骤模式不可能:运动激活 Homing procedure not possible:

Movement active

5019: 寻参参数超出有效值 Homing parameter outside the valid range

Info('PARID'): Parameter ID

5020: 寻参步骤不可能;两个限位开关关闭 Homing procedure not possible: Both

limit switches are closed

5021: 限位开关关闭;无方向改变用于寻参 Limit switch closed: No direction

change for this homing mode

5022: 第二个限位开关信号收到:参考开关信号未发现 Second limit switch signal

received: Reference switch not found

5023: 对于当前运动方向收到不正确的限位开关信号 Incorrect limit switch signal

received for current movement direction

5024: 循环设置数据模式放弃:设定位置丢失 Cyclic set value mode aborted: Set

positions missing

5025: 设置参考点位置偏

差用于修正计数范围不可能 Set homing offset with correction of counting range

not possible

5026: 基本运动参数超过速度限制 Basis movement parameter (with override)

exceed speed limit value

5027: 基本运动参数超过加速度限制 Basis movement parameter (with override)

exceed acceleration limit value

5028: 当前运动不是基本运动 Current movement is no basis movement

5029: 触发忽略-保持位置超过软限位 Trigger ignored - remaining distance

exceeds SW limit

5030: 寻参步骤模式不可能:位置控制器激活 Homing procedure mode not

possible: Position controller active

5031: 寻参步骤模式不可能:循环设值模式关闭 Homing procedure mode not

possible: Cyclic set values mode is off

5101: 凸轮曲线补偿:超出界限值 Cam profile compensation gears: Limit values

exceeded

5102: 过多的变化在每个凸轮曲线(主周期过短) Too many changes of cam

profile per cycle (master period too short)

5103: 从触发先进先出满 Slave trigger FIFO full

5104: 从触发先进先出空 Slave trigger FIFO empty

5105: 主触发先进先出满 Master trigger FIFO full

5106: 主触发先进先出空 Master trigger FIFO empty

5107: 启动凸轮曲线连接不可能:参数超出有效值 Start cam profile linkage not

possible: Parameter outside the valid range

Info('PARID'): Parameter ID

5108: 主补偿触发先进先出满 Master compensation trigger FIFO full

5109: 主补偿触发先进先出空 Master compensation trigger FIFO empty

5110: 凸轮曲线连接放弃:循环设定位置丢失 Cam profile linkage aborted: Cyclic

set positions missing

5111: 凸轮曲线连接放弃:编码器错误 Cam profile linkage aborted: Encoder error

5112: 命令不允许:凸轮曲线连接未激活 Command not allowed: Cam profile

linkage not active

5113: 命令不允许:控制器仍激活 Command not allowed: Controller is still active

5114: 写参数不允许:凸轮曲线连接激活 Write parameter not allowed: Cam

profile linkage active

5115: 重启命令不可能:凸轮时序以前从未激活 Restart command not possible:

The cam automat was never active before

5201: 写参数不允许:鼓序列激活 Write parameter not allowed: Drumsequencer

active

5202: 鼓序列发生器:位置不在上升顺序 Drumsequencer: Switch positions not in

ascending order

5300: 数据块上载无效: Data block for upload is not available

5302: 写参数不允许:凸轮时序激活 Write parameter not allowed: Cam automat

active

5303: 凸轮曲线未提供索引 Cam profile data no

t available at index

5304: 格式错误在凸轮曲线数据 Format error in cam profile data

Info(UINT): Detail

5306: 补偿:入口速度超限 Compensation gears: Speed for entrance exceeds

limit value

5307: 补偿:连接速度超限 Compensation gears: Speed for connection exceeds

limit value

5308: 补偿:最大爬坡超出 Compensation gears: Maximum jolt exceeded

5311: 凸轮时序:事件指向未初始化状态 Cam automat: Event leads to non

initialized state

5312: 仅事件类型ncTRIGGER1/2 能进入ncLATCHPOS 补偿

Only event type ncTRIGGER1/2 possible for entry in ncLATCHPOS

compensation

5315: 下载错误:凸轮曲线数据被凸轮时序使用 Download error: Cam profile data

in use by cam automat

5316: 事件类型ncST_END+ncNEGATIVE 不能进入补偿

Event type ncST_END+ncNEGATIVE is not possible for entry in compensation

gears

5317: 启动凸轮时序指向未初始状态 Start of cam automat leads to non initialized

state

5318: 主轴相对位置高于凸轮曲线周期 Relative distance of master axis higher

than cam profile period

5319: 凸轮曲线数据不能用于状态0 Cam profile data not allowed for state 0

6000: 主站采样时间不是位置控制器采样时间的整数倍

Master sampling time is not a multiple of position controller sampling time

6001: 同步控制器:同步报文超时 Sync controller: Timeout for sync telegram

occured

6002: 同步控制器:系统时间偏差超出

Sync Controller: Error tolerance of system time difference exceeded

6003: 控制器在位置模式仍激活 Controller is still active in position mode

6004: 控制器在速度模式仍激活 Controller is still active in speed mode

6005: 控制器在力矩模式仍激活 Controller is still active in torque mode

6006: 控制器在定子电压旋转磁场模式仍激活 Controller is still active in stator

voltage rotating field mode

6007: 控制器在定子电流旋转磁场模式仍激活 Controller is still active in stator

current rotating field mode

6008: 控制器仍激活 Controller is still active

6009: 参数写保护对现有电机模式 Parameter is write protected for existing motor

type

6010: 参数写保护对现有编码器模式 Parameter is write protected for existing

encoder type

6011: 控制器不在速度模式 Controller is not in speed mode

6012: CAN 控制器:没有CAN 对象空闲 CAN controller: No CAN object free

6013: 双编码器控制器激活 Two encoder control active

6014: 驱动器初始化激活

Drive initialisation active

6015: CAN 控制器:CAN 总线接收干扰

CAN controller: CAN bus disturbance (receive error counter >= 96)

Info(USINT): Slot

6016: CAN 控制器:CAN 总线发送干扰 CAN controller: CAN bus disturbance

(transmit error counter >= 96)

Info(USINT): Slot

6017: 软件:看门狗激活 Software: Watchdog active

6018: 硬件:15 电源失败 Hardware: 15V power supply fail

6019: 硬件:IGBT 功率放大器过流 Hardware: Overcurrent in IGBT

6020: 硬件:24V 电源失败 Hardware: 24V power supply fail

6021: 启动锁出激活 Starting lockout active

6022: 电流控制器:允许电流偏差值超出 Current controller: Permissible current

offset values exceeded

6023: 硬件:累积错误激活 Hardware: Sum error active

6024: 电流记录在转变前 Current was latched befor conversion (OpSys error in

ABLS)

6025: 温度记录在转变前 Temperature was latched befor conversion (OpSys error

in ABLS)

6026: 保持制动器:定子电流超过限制 Holding brake: Stator current limit

exeeded during release

6027: 保持制动器:手动操作不允许 Holding brake: Manual operation not

permitted

6028: 保持制动器:低于电压/ 电流(接线,检查24VDC)

Holding brake: Undervoltage/-current (wire breakage, check 24V supply)

6029: 保持制动器:电压或电流失败(接线,检查24VDC)

Holding brake: Voltage- or currentfail (wire breakage, check 24V supply)

6030: 保持制动器:制动输出激活,但无制动进入电机数据

Holding brake: Brake output is active, but no brake entered in motor data

6031: 系统模块已检测 System module already deleted

6032: 接口:FPGA 组态错误 Interface: FPGA configuration error

Info(USINT): Slot

6033: EEPROM :重要数据无效 Serielles EEPROM: Critical datum is not valid

6034: 循环设置数值放弃:设定速度丢失 Cyclic set value mode aborted: Set

speeds missing

6035: 上载编码器未提供 Load encoder not available

6037: 力矩限制《0.0 Torque limit <= 0.0

6038: 力矩限制》最大允许力矩 Torque limit > maximum permissible torque

Info(REAL): Maximum permissible torque

6039: PID 控制器错误超限停止 PID controller error stop limit exceeded

Info(REAL): Current PID controller error

6040: 参数功能不支持Parameter function not supported. (Modul ?)

Info(UINT): Slot

7014: Endat 编码器:CRC 校验错误传送参数Endat encoder: CRC error during

transfer parameter

Info(USINT): Slot

7015: Endat 编码器:超时错误传送参数Endat encoder: Timeout error during

transfer parameter

Info(USINT): Slot

7016: Endat 编码器:繁忙错误传送参数Endat encoder: Busy error during

transfer parameter

Info(USINT): Slot

7017: Endat 编码器:错误读编码器参数Endat encoder: Error while reading

encoder parameter

Info(USINT): Slot

7019: OEM 数据无效OEM data not valid

Info(USINT): Slot

7020: OEM 数据:数据写错误OEM data: Data write error

Info(USINT): Slot

7021: Endat 编码器:超时错误读绝对位置Endat encoder: Timeout error while

reading absolut position

Info(USINT): Slot

7022: Endat 编码器:初始化未激活Endat encoder: Initialization is active

Info(USINT): Slot

7023: Endat 编码器:参数传送激活Endat encoder: Parameter transfer is active

Info(USINT): Slot

7025: OEM 数据:无效电机类型OEM data: Invalid motor type

7028: OEM 数据:数据模块不兼容现有操作系统

OEM data: Data modul not compatible with operating system

7030: Endat 编码器:模拟信号干扰Endat encoder: Analog track disturbance

Info(USINT): Slot

7032: Endat 编码器:未连接Encoder: No connection

Info(USINT): Slot

7036: 编码器:接口ID 无效(检查插槽和接口EEPROM 数据)

Encoder: Interface ID invalid (Check slot and Interface EEPROM data)

Info(USINT): Slot

7038: 编码器:位置数据不同步和绝对值)

Encoder: Position value not synchronous with absolute value

Info(USINT): Slot

7039: 增量编码器:电缆干扰A 线Incremental encoder: Cable disturbance track

A

Info(USINT): Slot

7040: 增量编码器:电缆干扰B 线Incremental encoder: Cable disturbance track

B

Info(USINT): Slot

7041: 增量编码器:电缆干扰R 线Incremental encoder: Cable disturbance track

R

Info(USINT): Slot

7042: 增量编码器:边沿位置信号太小Incremental encoder: Edge distance of

quadrature signal too small

Info(USINT): Slot

7043: SSI 编码器:电缆干扰D 线SSI encoder: Cable disturbance track D

Info(USINT): Slot

7044: SSI 编码器:极性SSI encoder: Parity

Info(USINT): Slot

7045: 旋变:电缆干扰核对Resolver: Cable disturbance (plausibility check)

Info(UINT): Slot

7046: 旋变:电缆干扰Resolver: Cable disturbance

Info(UINT): Slot

7200: DC 连接电路:硬件过压检测 DC link circuit: Overvoltage detected by

Hardware

Info(REAL): DC link voltage

7201: DC 连接电路:过压DC link circuit: Overvoltage

Info(REAL): DC link voltage

7210: DC 连接电路:电压太低或不稳定DC link circuit: Voltage too low or

unstable (check the power line)

Info(REAL): DC link voltage

7211: DC 连接电路:电压断线检查动力线DC link circuit: Voltage breakdown

(check the power line)

Info(REAL): Low voltage limit

7212: DC 连接电路:电压断线急停中断

DC link circuit: Voltage breakd

own -> Emergency-Stop interrupted

Info(REAL): Low voltage limit

7213: DC 连接电路:时间常数决定激活动力线

DC link circuit: Time constant determination with activ power line

Info(REAL): DC link voltage

7214: DC 连接电路:电阻过热(太多动力线失败)

DC link circuit: Inrush resistor hot (To much power line fails)

7215: DC 连接电路:至少一相动力线失败DC link circuit: At least one phase of

the power line failed

7216: DC 连接电路制动:泄放功率超过最大值DC link circuit: Bleeder power

higher than maximum value

7300: 数字量IO:IO 组态无效Digital IO: IO Configuration invalid

Info(UINT): Slot

7301: 数字量IO:接口未提供Digital IO: Interface not available

Info(UINT): Slot

7302: 数字量IO:错误设置分辨率或增量Digital IO: Set wrong resolution or

increment error

Info(UINT): Measured increments per encoder revolution

7400: 无效参数ID 用于循环数据Invalid parameter ID for cyclic data

7401: 参数位置超过最大数据长度Parameter position exceeds maximum data

length

7402: 处理参数步骤放弃:写错误Processing of parameter sequence aborted:

Write error

Info(UINT): Index of parameter

7403: 处理参数步骤仍激活Processing of parameter sequence is still active

7404: 参数步骤未提供在索引Parameter sequence not available at index

8001: EEPROM 选择无效EEPROM select not valid

8002: EEPROM 地址无效EEPROM address not valid

8003: 列表索引无效Table index not valid

8004: EEPROM 变量类型无效EEPROM variable type not valid

8005: EEPROM 类型无效EEPROM type not valid

8006: EEPROM 参数数值为零Value of EEPROM parameter is zero

Info(UINT): EEPROM Parameter ID

8007: EEPROM 参数数值无效Value of EEPROM parameter is not valid

Info(UINT): EEPROM Parameter ID

8008: EEPROM 参数数值大于最大值Value of EEPROM parameter higher than

maximum value

Info(REAL): Maximum value

8009: EEPROM 参数数值小于最小值Value of EEPROM parameter lower than

minimum value

Info(REAL): Minimum value

8010: 模块标志无效Modul identification not valid

Info(INT): Modul (0 processor plate,1 power plate,2 slot1,3 slot2,4 slot3,5 slot4)

8020: 无效开关频率Invalid switch frequency

9000: IGBT 表面温度过温Heatsink overtemperature

Info(REAL): Heatsink temperatur

9002: IGBT 表面温度传感器未连接或损坏

Temperature sensor in the heatsink is not connected or destroyed

Info(REAL): Heatsink temperatur

9003: IGBT 表面温度传感器未连接或损坏

Temperature sensor in the heatsink is not connected or destroyed

Info(REAL): Heatsink temperatur

9010: 电机超温Motor overtemperature

Info(REAL): Motor temperatur

9012: 电机温度传感器未连接或损坏Motor temperature sensor is not connected

or destroyed

Info(REAL): Motor temperatur

9013: 短路电机温度Shorted Motor temperature

Info(REAL): Motor

temperatur

9030: IGBT PN 结超温Junction overtemperature

Info(REAL): Junction temperatur

9031: IGBT PN 结超温(没有急停)Junction overtemperature (Without

Emergency-Stop)

Info(REAL): Junction temperatur

9040: 制动系统超温Bleeder overtemperature

Info(REAL): Bleeder temperatur

9050: 峰值电流过载Peak current overload (i2t)

Info(REAL): Peak current load [%]

9060: 持续电流过载Continuous current overload (i2t)

Info(REAL): Continuous current load [%]

9070: 电机超温(温度模型)Motor overtemperature (temperature model)

Info(REAL): calculated Motor temperatur

9300: 电流控制器(IGBT 功率放大器过流)电流不可测

Current controller: Overcurrent IGBT (current not measurable)

Info(REAL): Absolute value of the biggest phase current

9301: 电流控制器:停止因为IGBT 功率放大器过流

Current controller: Stop due to overcurrent IGBT (current not measurable)

Info(REAL): Modulo of the current phasor

32001: 调用CAN_xopen() 错误Error at call of CAN_xopen()

Info(UINT): Status of CAN_xopen()

32002: 用于广播命令定义写COB 时错误Error at definition of Write COB for

Broadcast Command

Info(UDINT): CAN-ID (in HB und MHB) and Status of CAN_defineCOB() (in MLB

and LB)

32003: 用于读请求定义写COB 时错误Error at definition of Write COB for

Parameter Read Request

Info(UDINT): CAN-ID (in HB und MHB) and Status of CAN_defineCOB() (in MLB

and LB)

32004: 用于写请求定义写COB 时错误Error at definition of Write COB for

Parameter Write Request

Info(UDINT): CAN-ID (in HB und MHB) and Status of CAN_defineCOB() (in MLB

and LB)

32005: 用于读反应定义读COB 时错误Error at definition of Read COB for

Parameter Read Response

Info(UDINT): CAN-ID (in HB und MHB) and Status of CAN_defineCOB() (in MLB

and LB)

32006: 用于写反应定义读COB 时错误Error at definition of Read COB for

Parameter Write Response

Info(UDINT): CAN-ID (in HB und MHB) and Status of CAN_defineCOB() (in MLB

and LB)

32007: 用于监视驱动器数据定义读COB 错误

Error at definition of Read COB for Monitor Data from the drive

Info(UDINT): CAN-ID (in HB und MHB) and Status of CAN_defineCOB() (in MLB

and LB)

32008: 在发送读反应错误(网络错误?)Error at sending Read Request (network

error ?)

Info(UINT): Status of CAN_sendCOB()

32009: 在发送写反应错误(网络错误?)Error at sending Write Request

(network error ?)

Info(UINT): Status of CAN_sendCOB()

32010: 对读反应的驱动无反应(驱动存在于网络?)

No response of drive for Read Request (exists drive in network ?)

32011: 对写反应的驱动无反应(驱动存在于网络?)

No response of drive for Write Request (exists drive in network ?)

32012: 在系统模块读描述时错误Error at reading module description of system

module

32013: 驱动器未装操作系统No operating system existing on the drive

32014: 操作系统版本和NC 管理器版本不兼容

Operating system version on the drive not compatibel with NC manager

version

Info(UINT): Operating system version on the drive (hexadecimal)

32015: 创建信息请求错误Error at creation of message queue

Info(UINT): Status of q_create()

32016: 对NC 管理器任务发送空闲时间命令错误

Error at sending a idle time command to the NC Manager Task

Info(UINT): Status of q_send()

32017: 在启动操作系统后,错误的引导状态Wrong boot state after start of

operating system

Info(UINT): Boot state

32018: 在系统模块中无效的参数ID Invalid Parameter ID in system module

32019: 下载NC 系统模块不允许(系统模块存在PCC)

Download of NC system module not allowed (the module exists on the PCC)

32020: 在NC 管理器中初始驱动不能读出系统模块数据

System module data could not be read from the drive at NC manager INIT

32021: 在下载后,从驱动器中不能够读出系统模块

System module data could not be read from the drive after download

32022: 在下载前,访问数据块放弃时错误Error at abort of data block access

before download

32023: 在下载前,读引导状态区错误Error at reading boot state before

download

32024: 在SW 复位下载前,读引导状态区错误Error at reading boot state after

SW Reset before download

32025: 在SW 复位下载前,状态区错误Wrong boot state after SW Reset before

download

32026: 用于下载初始数据块写访问错误Error at INIT of data block write access

for download

32027: 用于下载发送数据标识错误Error at sending data segment for download

32028: 用于下载发送数据标识超时Timout after sending data segment for

download

32029: 用于下载发送数据标识反应错误Response error after sending data

segment for download

32030: 在下载后,命令烧结系统模块命令错误Error at command for burn system

module after download

32031: 在下载后,读状态烧结系统模块命令错误

Error at reading status for burn system module after download

32032: 在下载后,烧结系统模块命令错误Error at burn system module after

download

32033: 在下载后,烧结系统模块命令超时Timeout at burn system module after

download

32034: 在SW 复位下载前错误Error at SW Reset before download

32035: 在SW 复位下载后错误Error at SW Reset after download

32036: 在下载后,不同系统模块数据Different system module data after

download

32037: 错误信息丢失因为FIFO 溢出(确认错误)

Error message(s) lost because of FIFO overflow (acknowledge errors)

32038: 查找初始化参数数据模块错误Error at searching INIT parameter data

module

Info(UINT): Status of function MO_modul_search()

32039: 读初始化参数数据模块错误Error at reading INIT parameter data module

Info(UINT): Status of function MO_read()

32040: 初始化参数数据模块版本和NC 管理器版本不兼容

Version of INIT parameter data module is not compatible to NC manager

Info(UINT): Version of INIT parameter data module (hexadecimal)

32041: acp10cfg 模块不存在The module acp10cfg does not exist

32042: acp10cfg 模块不是NC 数据模块The module acp10cfg is no NC data

module

32043: acp10cfg 模块不是有效的NC 模块类型The NC module type of the

module acp10cfg is invalid

32044: acp10cfg 模块NC 模块类型不可读The NC module type of the module

acp10cfg cannot be read

32045: acp10cfg 模块数据地址不可读The data address in module acp10cfg

cannot be read

32046: acp10cfg 模块版本不兼容NC 管理器

Version of the module acp10cfg is not compatible with NC manager

32047: acp10cfg 模块站号无效 A node number in module acp10cfg is invalid

32048: acp10cfg 模块站号多次使用A node number in module acp10cfg is

multiple used

32049: 跟踪启动已经激活Trace is already active at trace start

32050: 跟踪数据上载已经激活A Trace Data Upload is already active

32051: 用于跟踪数据上载的跟踪状态无效Invalid Trace Status for Trace Data

Upload

32052: 用于跟踪数据上载ev_send() 错误Error at ev_send() for Trace Data Upload

Info(UINT): Status of function ev_send()

32053: 用于参数读请求2 的写COB 定义错误

Error at definition of Write COB for Parameter Read Request 2

Info(UDINT): CAN-ID (in HB und MHB) and Status of CAN_defineCOB() (in MLB

and LB)

32054: 用于参数写请求2 的写COB 定义错误

Error at definition of Write COB for Parameter Write Request 2

Info(UDINT): CAN-ID (in HB und MHB) and Status of CAN_defineCOB() (in MLB

and LB)

32055: 用于参数读请求2 的读COB 定义错误

Error at definition of Read COB for Parameter Read Response 2

Info(UDINT): CAN-ID (in HB und MHB) and Status of CAN_defineCOB() (in MLB

and LB)

32056: 用于参数写请求2 的写COB 定义错误

Error at definition of Read COB for Parameter Write Response 2

Info(UDINT): CAN-ID (in HB und MHB) and Status of CAN_defineCOB() (in MLB

and LB)

32057: 访问高速任务列表错误Error at access to HS task class table

Info(UINT): Status of SS_get_entry()

32058: 访问任务列表错误Error at access to task class table

Info(UINT): Status of SS_get_entry()

32059: 访问高速任务列表参数tk_no 无效Parameter tk_no invalid for access to

task class table

Info(UINT): Value of tk_no

32060: 从驱动得到的循环数据超时》标志无效(网络错误?)

Timeout for cyclic data from drive => Indications invalid (network error ?)

32061: 发送读请求报文超时(网络错误?)

Timeout for sending a Read Request Telegram (network error ?)

32062: 发送写请求报文超时(网络错误?)

Timeout for sending a Write Request Telegram (network error ?)

32063: 数据地址为零(设/ 读参数通过

SERVICE 通道)

Data address zero (set/read parameter via service interface)

32064: 参数类型不能设置可选的

ncDATA_TEXT Parameter with that type cannot be set with option

ncDATA_TEXT

32065: 参数类型不能读取可选的

ncDATA_TEXT Parameter with that type cannot be read with option

ncDATA_TEXT

32066: 参数ID 零(设/ 读参数通过SERVICE 通道)

Parameter ID zero (set/read parameter via service interface)

32067: 参数ID 无效(设/ 读参数通过可选的ncDATA_TEXT )

Parameter ID invalid (set/read parameter with option ncDATA_TEXT)

32068: 下载新的BS Loader acp10bsl 版本是必须的

Download of new version of BS Loader acp10bsl to the drive is necessary

Info(UINT): Version of BS Loader on the drive (hexadecimal)

32069: acp10cfg 模块的电机参数数据地址是不可读的

The data address of the motor parameters in module acp10cfg cannot be read

32070: acp10cfg 模块的电机参数驱动未发现Drive for motor parameters in

module acp10cfg not found

Info(UINT): Interface index (in HB) and node number (in LB) of this drive

32071: 电机参数无效(升级AS 必须)

The motor parameters are invalid (an update of AutomationStudio is necessary)

32072: 在SW 复位后错误的引导状态Wrong boot state after SW Reset

Info(UINT): Boot state

32073: 下载NC 系统模块:读取BS Loader 中的NC HW 版本错误

Download of NC system module: Error at reading NC HW Version of BS Loader

32074: 不兼容NC HW 版本:下载BS Loader 不可能

Incompatible NC HW Version: Download of BS Loader not possible

32075: 不兼容NC HW 版本:下载操作系统

不可能Incompatible NC HW Version: Download of operating system not

possible

32076: FIFO 用于高级别信息到NC 管理器的任务满

FIFO for messages with high priority to NC Manager Task is full

32095: 在CAN-组态模块的驱动组的数值高于最大值

Value of drive group in CAN-CFG-Module higher than maximum value

Info(UINT): Maximum value

32096: 用于跟踪数据上载的数据缓冲区的尺寸在acp10cfg 中

太小Size of data buffer for trace data upload in module acp10cfg too small

32097: 用于CAN 接口的acp10cfg 的计数值为零

The count of used CAN interfaces in module acp10cfg is zero

32098: acp10cfg 模块的数据是空 The Data section of module acp10cfg is empty

Info(UINT): Number of data section

32099: acp10cfg 模块的数据长度太小Length of data section of module

acp10cfg is too small

Info(UINT): Number of data section

32100: 用于NC 错误管理的内存不能被收集

Memory for NC error text management cannot be allocated

Info(UINT): Status of SM_malloc()

32101: 在BR 系统模块列表的NC 访问错误Error at access to NC error text module

in B&R module table

Info(UINT): Status of SS_get_entry()

32102: 错误文本模块的版本ID 不同于NC 管理器

Version ID of error text module not equal to that

of NC manager

32103: 错误文本模块的数据不可读Data section of error text module cannot be

read

Info(UINT): Number of data section

32104: 错误文本模块的数据是空Data section of error text module is empty

Info(UINT): Number of data section

32105: 错误文本模块的数据长度太小Length of data section of error text module

is too small

Info(UINT): Number of data section

32106: 错误文本模块不同于NC 管理器的错误列表

Error list of error text module not equal with that of NC manager

Info(UINT): First invalid error number

32107: 错误文本模块不同于NC 管理器的参数列表

Parameter list of error text module not equal with that of NC manager

Info(UINT): First invalid parameter ID

32108: 错误文本模块的最后一个错误代码不等于65535

The last error number of error text module is not equal to 65535

32109: 错误文本模块的最后一个参数ID 不等于65535

The last parameter id of error text module is not equal to 65535

32110: 在CAN-组态模块的数据长度不可读Length of data section of CAN-CFG-

Module cannot be read

Info(UINT): Status of function MO_section_lng()

32111: 在CAN-组态模块的数据长度太小Length of data section of CAN-CFG-

Module is too small

Info(UINT): Expected length

32112: 在CAN-组态模块的数据地址不可读The data address in the CAN-CFG-

Module cannot be read

Info(UINT): Status of function MO_read()

32113: 在CAN-组态模块的势能代码无效The enable code in the CAN-CFG-

Module is invalid

32114: 在CAN-组态模块的保留区的数据不等于零

Values not equal to zero in reserved area of CAN-CFG-Module

32115: 在CAN-组态模块的基本CAN ID 用于写/ 读通道1 无效

The basis CAN ID for WR/RD channel1 in the CAN-CFG-Module is invalid

32116: 在CAN-组态模块的基本CAN ID 用于写/ 读通道2 无效

The basis CAN ID for WR/RD channel2 in the CAN-CFG-Module is invalid

32117: 在CAN-组态模块的基本CAN ID 用于写/ 读通道3 无效

The basis CAN ID for WR/RD channel3 in the CAN-CFG-Module is invalid

32118: 在CAN-组态模块的基本CAN ID 用于监视数据无效

The basis CAN ID for monitor data in the CAN-CFG-Module is invalid

32119: 在CAN-组态模块的基本CAN ID 用于对驱动器循环数据无效

Invalid basis CAN ID for cyclic data to the drive in CAN-CFG-Module

32120: 在CAN-组态模块的基本CAN ID 用于从驱动器循环数据无效

Invalid basis CAN ID for cyclic data from the drive in CAN-CFG-Module

32121: 在CAN-组态模块的基本CAN ID 用于同步报文无效

The CAN ID for the SYNC telegram in the CAN-CFG-Module is invalid

32122: 在CAN-组态模块的基本CAN ID 用于广播报文无效

The CAN ID for the braodcast command in the CAN-CFG-Module is invalid

32123: 定义读COB 对WR2 写请求错误(特殊模式)

Error at definition of Read COB for WR2 Request (special mode)

Info(UDINT): CAN

-ID (in HB und MHB) and Status of CAN_defineCOB() (in MLB and LB)

32124: 定义读COB 对WR2 写响应错误(特殊模式)

Error at definition of Read COB for WR2 Response (special mode)

Info(UDINT): CAN-ID (in HB und MHB) and Status of CAN_defineCOB() (in MLB

and LB)

32125: 定义读COB 对RD2 读请求错误(特殊模式)

Error at definition of Read COB for RD2 Request (special mode)

Info(UDINT): CAN-ID (in HB und MHB) and Status of CAN_defineCOB() (in MLB

and LB)

32126: 定义读COB 对RD2 读响应错误(特殊模式)

Error at definition of Read COB for RD2 Response (special mode)

Info(UDINT): CAN-ID (in HB und MHB) and Status of CAN_defineCOB() (in MLB

and LB)

32127: 用于广播命令检测写COB 时错误(特殊模式)

Error at deletion of Write COB for Broadcast Command (special mode)

Info(UDINT): CAN-ID (in HB und MHB) and Status of CAN_deleteCOB() (in MLB

and LB)

32128: 用于广播命令检测读COB 时错误(特殊模式)

Error at definition of Read COB for Broadcast Command (special mode)

Info(UDINT): CAN-ID (in HB und MHB) and Status of CAN_defineCOB() (in MLB

and LB)

32129: 从驱动器对于循环用户数据读COB 出错(特殊模式)

Error at Read COB Def. for cyclic user data from the drive (special mode)

Info(UDINT): CAN-ID (in HB und MHB) and Status of CAN_defineCOB() (in MLB

and LB)

32130: 具体仅允许一个CAN 接口This special mode is only allowed with one

CAN interface

Info(UINT): Count of used CAN interfaces

32131: 具体数据模块不存在The specified NC data module does not exist

32132: 具体不在NC 数据模块中The specified module is no NC data module

32133: 具体NC 数据模块的NC 模块类型无效NC module type of the specified

NC data module is invalid

Info(UINT): Requested type (in HB) and type of NC data module (in LB)

32134: 具体NC 数据模块的NC 模块类型不可读

The NC module type of the specified NC data module cannot be read

Info(UINT): Status of function MO_read()

32135: 具体NC 数据模块的数据地址不可读

The data address of the specified NC data module cannot be read

Info(UINT): Status of function MO_read()

32136: 具体NC 数据模块的数据空The Data section of the specified NC data

module is empty

Info(UINT): Number of data section

32137: 用于数据块操作的结构数据地址为零Data address of structure for a data

block operation is zero

32138: 数据地址为零(用户数据块操作)Data address zero (user data for data

block operation)

32139: 数据长度零(用户数据块操作)Data length zero (user data for data block

operation)

32140: 数据块操作:数据模块名称或地址必须为零)

Data block operation: Data module name or data address must be zero

32141: 在参数步骤中无效的数据格式Invalid data format in a parameter

sequence

32142: 参数的ID 或类型无效在参数步骤文本

格式

ID or type of a parameter invalid in parameter sequence with text format

Info(UDINT): Index of this parameter in the parameter sequence

32143: 参数数据在参数步骤大于4 个字节

Data of a parameter in a parameter sequence longer than 4 bytes

Info(UDINT): Index of this parameter in the parameter sequence

32200: 调用plAcycWrite() 错误Error at call of plAcycWrite()

Info(UINT): Status of plAcycWrite()

32201: 调用plAcycWrite() 错误Error at call of plAcycWrite()

Info(UINT): Status of plAcycWrite()

32202: 调用plAcycRead() 错误Error at call of plAcycRead()

Info(UINT): Status of plAcycRead()

32203: 调用plAcycRead() 错误Error at call of plAcycRead()

Info(UINT): Status of plAcycRead()

32204: 通过循环通道读参数超时(驱动器存在于网络?)

Timeout for parameter read via acyclic channel (exists drive in network ?)

32205: 通过循环通道写参数超时(驱动器存在于网络?)

Timeout for parameter write via acyclic channel (exists drive in network ?)

32206: 循环通道1:不管写反应读请求Cyclic channel: Read Request in spite of

Wait for Response

32207: 循环通道1:不管写反应写请求Cyclic channel: Write Request in spite of

Wait for Response

32500: FIFO 信息已存在The Message FIFO is already existing

32501: 创建FIFO 信息错误Error at creation of Message FIFO

Info(UINT): Status of RtkCreateFifo()

32502: 命令标志已存在The Command Semaphore is already existing

32503: 创建命令标志错误Error at creation of Command Semaphore

Info(UINT): Status of RtkCreateSemaphore()

32504: NC 管理器空闲任务已存在The NC Manager Idle Task is already existing

32505: 创建NC 管理器空闲任务错误Error at creation of Nc Manager Idle Task

Info(UINT): Status of RtkCreateTask()

32506: 读任务级别循环时间错误Error reading Taskclass Cycle Time

Info(UINT): Status of GetTaskclassCycleTime()

32507: 读任务级别容忍错误Error reading Taskclass Tolerance

Info(UINT): Status of GetTaskclassMaxCycleTime()

32508: 在发送一个空闲时间命令对NC 管理器任务错误

Error at sending a idle time command to the NC Manager Task

Info(UINT): Status of RtkWriteFifo()

33000: 主循环时间不是通信循环时间的整数倍

Master cycle time is not a multiple of communication cycle time

36001: 参数限定在有效范围Parameter limited to valid range

36002: 位置环控制的整个时间限定在规定时间

Total time for the position loop controller limited to prediction time

37101: 从轴上补偿距离计算限定在最大值

Calculated compensation distance on slave axis limited to maximum

37102: 从轴上补偿距离计算限定在最小值

Calculated compensation distance on slave axis limited to minimum

37103: 从触发超出窗口Slave trigger out of window

37104: 从触发丢失Slave trigger missing

37105: 主补偿触发超出

窗口Master compensation trigger out of window

37106: 主补偿触发丢失Master compensation trigger missing

37107: 不可替换实际/ 设定位置到更高在控制器开时

Displacement actual-/setposition to high during 'controller switch on'

37108: 主轴上补偿距离计算限定在最小值

Calculated compensation distance of master axis limited to minimum

37109: 从触发超出窗口Master trigger out of window

37110: 主位置在启始高于触发1 位置Masterposition at start higher than 1.

triggerposition

37111: 凸轮曲线数据:在幂数据Y (X)和从周期不同

Cam profile data: Difference between polynomial value y(xn) and slave period

Info(REAL): Difference

37112: 凸轮曲线数据幂超过限定值

Polynomial within cam profile data exceeds limit value

Info(UINT): Detail

38000: 电流控制器:计算电流偏差不可能Current controller: Calculation of

current offset not possible

38001: 电流元件限定超过最大变频电流

Current quadrature component limited to maximal inverter current

Info(REAL): Maximal inverter current

39001: Endat 编码器:位置修正激活Endat encoder: Position correction active

Info(USINT): Slot

39002: 旋变:速度限定在14 位分辨率超出Resolver: Speed limit for 14 bit

resolution exceeded

Info(USINT): Slot

39003: Endat 编码器:报警置位Endat encoder: Alarm bit is set

Info(USINT): Slot

39004: Endat 编码器:报警位-亮失败Endat encoder: Alarm bit - Lighting failure

Info(USINT): Slot

39005: Endat 编码器:报警位-信号放大太小Endat encoder: Alarm bit - Signal

amplitude too small

Info(USINT): Slot

39006: Endat 编码器:报警位-检测位置值Endat encoder: Alarm bit - Defective

position value

Info(USINT): Slot

39007: Endat 编码器:报警位-过压Endat encoder: Alarm bit - Overvoltage

Info(USINT): Slot

39008: Endat 编码器:报警位-低压Endat encoder: Alarm bit - Undervoltage

Info(USINT): Slot

39009: Endat 编码器:报警位-过流Endat encoder: Alarm bit - Overcurrent

Info(USINT): Slot

39010: Endat 编码器:报警位-需要更换电池Endat encoder: Alarm bit - Battery

change required

Info(USINT): Slot

39011: Endat 编码器:警告位:频率太大Endat encoder: Warning bit -

Frequency too large

Info(USINT): Slot

39012: Endat 编码器:警告位:温度太大Endat encoder: Warning bit -

Temperature too large

Info(USINT): Slot

39013: Endat 编码器:警告位:保留灯到达Endat encoder: Warning bit -

Lighting reserve reached

Info(USINT): Slot

39014: Endat 编码器:警告位:电池充电太小Endat encoder: Warning bit -

Battery charge too small

Info(USINT): Slot

39015: Endat 编码器:警告位:参考位未到达Endat encoder: Warning bit -

Reference point not reached

Info(USINT): Slot

39016: 增量编码器评估:频率太大Incremental encoder emulation: Freqency too

large

Info(UINT): Slo

t

39017: Endat 编码器:读位置CRC 校验错Endat encoder: CRC error while

reading position

Info(USINT): Slot

39200: DC 连接电路:单相功率线或缺相DC link circuit: Single phase power line

or less line voltage

Info(REAL): Nominal dc bus voltage

39300: 数字量IO:通道1 不能设置为输入Digital IO: Channel can not be set.

Configurated as input.

Info(UINT): Slot

39301: 数字量IO:24V 电源故障Digital IO: 24V power supply fail

Info(UINT): Slot

39302: 数字量IO:1-4 诊断位激活(IO 电流,24V 供电)

Digital IO 1-4: Diagnose bit active (IO current, 24V supply)

Info(UINT): Slot

39303: 数字量IO:5-8 诊断位激活(IO 电流,24V 供电)

Digital IO 5-8: Diagnose bit active (IO current, 24V supply)

Info(UINT): Slot

39304: 数字量IO:9 诊断位激活(IO 电流,24V 供电)

Digital IO 9: Diagnose bit active (IO current, 24V supply)

Info(UINT): Slot

39305: 数字量IO:10 诊断位激活(IO 电流,24V 供电)

Digital IO 10: Diagnose bit active (IO current, 24V supply)

Info(UINT): Slot

39306: 数字量IO:9-10 过流Digital IO 9-10: Overcurrent

Info(UINT): Slot

41001: IGBT 表面温度超温Heatsink overtemperature

Info(REAL): Heatsink temperatur

41011: 电机超温Motor overtemperature

Info(REAL): Motor temperatur

41031: IGBT PN 结超温Junction overtemperature

Info(REAL): Junction temperatur

41041: 制动系统超温Bleeder overtemperature

Info(REAL): Bleeder temperatur

41051: 峰值电流过载Peak current overload (i2t)

Info(REAL): Peak current load [%]

41061: 持续电流过载Continuous current overload (i2t)

Info(REAL): Continuous current load [%]

41070: 电机超温(温度模型)Motor overtemperature (temperature model)

Info(REAL): Calculated motor temperatur

41300: 电流控制器:IGBT 功率过流Current controller: Overcurrent IGBT (current

not measurable)

Info(REAL): Modulo of the current phasor

41301: 电流控制器:IGBT 功率过流停止

Current controller: Stop due to overcurrent IGBT (current not measurable)

Info(REAL): Modulo of the current phasor

64001: ncalloc 小于在NC 管理器定义的任务级别

ncalloc in slower task class than defined for NC Manager Task

64003 :POWERLINK 插线错误,

64500: 正向速度限定激活Positive speed limiter active

64501: 负向速度限定激活Negative speed limiter active

64502: 正向加速力矩限定激活Positive direction acceleration torque limiter

active

64503: 负向加速力矩限定激活Negative direction acceleration torque limiter

active

64504: 正向减速力矩限定激活Positive direction deceleration torque limiter

active

64505: 负向减速力矩限定激活Negative direction deceleration torque limiter

active

64506: 再生电源限定激活(减速到高)Regenerativ power limiter active

(deceleration to high)

65535: 反应错误Response Error

注意:根据ACP10 SW

版本不同,以上ACOPOS 出错代码表会有所不同,具体信息请查阅AS 在线帮助。