Protocol Gateway

Data Sheet

CAS-2700-11

INCON TS 5 / 550 / 5000

Modbus (RTU and TCP) and BACnet and HTML

Gateway

Description

The Veeder Serial Driver allows the Gateway to poll INCON TS 550/5000 Panels for status, real

time and configuration data. Thus the driver can be used to read Tank Inventory, System Status,

Tank Alarms, Sensor Alarms, and more.

The Gateway serves data from the INCON panel as Modbus, BACnet or Web data. The gateway

supports all these options simultaneously. Use the data you want and ignore the other.

The Gateway connects to the INCON Panel, reads data and stores it internally. When a remote

system requests data, this data is served in a form that is appropriate to the protocol. In the event

that the connection to the INCON Panel is lost, or data cannot be read, the gateway can signal

this to the remote data client.

The gateway requires minimal configuration and can be considered a plug and play component of

a system, in that it is ready to operate out of the box with the default configuration.

The gateway uses a serial driver over RS232 and an Ethernet based TSA XML protocol driver to

connect and exchange data with the INCON Panel. The Panel must have a suitable

RS232 card installed.

Specs.

UL and ULc approved

10/100BaseT with RJ-45 connector

1x RS232 Port

1x RS485 Port (Different Models have additional ports)

2MBytes flash memory, 8MBytes of SDRAM

Power: 5-24VDC

Operating Temperature: 0 to 70 C

Dimensions: 4.2" x 3.25" x 1"

LEDs: Link, Speed/Data, Power

2013

© Chipkin Automation Systems,

3381 Cambie St, #211, Vancouver, BC, Canada, V5Z 4R3

Tel:186****1657, Fax:

(416) 915-4024

Email: *************** Website:

Page 1 of 8

Protocol Gateway

Data Sheet

Max Nodes Supported

Gateway Mode

Client

Server

Connection Information - Port 0: Modbus RTU Server Port

Connection type:

Baud Rates:

Data Bits:

Stop Bits:

Parity:

Hardware interface:

Multidrop Capability

Connection Information - Port 1: Veeder Root Client Port

Connection type:

Baud Rates:

Data Bits:

Stop Bits:

Parity:

Hardware interface:

Multidrop Capability

Devices tested

Device

INCON TS550

INCON TS5000

Nodes

1

0

Comments

Only 1 INCON Panel per connection

Not supported or documented.

RS485 (Jumper change to RS232)

9600; 19200 Baud

8

1

None

N/A

Yes

EIA232

Driver Supports: 1200, 2400, 4800, 9600, 19200 Baud

Driver Supports: 7, 8

Driver Supports: 1, 2

Driver Supports: Odd, Even, None

N/A

No

Tested (FACTORY, SITE)

Tested

Tested

2013