2024年5月4日发(作者:)
Voltage meter, Ampere meter, ST-72 by SEW, Taiwan
Voltage meter
↓Switch off the machine power
↓Detach the Voltage meter
↓Connect the voltage meter to AC voltage current stand
(Ex.: Yokogawa 2558 AC voltage current standard)
↓ Switch on the voltage current stand, and check the below voltages and record the
result
Voltage Standard (V)
0
100
350
380
400
Read value of voltage meter (V)
Deviation
↓ If there is any deviation between voltage standard and the read value, please
remove the cover and adjust the screw until the read value is correct.
(CAUTION: BE CAREFUL THE HIGH VOLTAGE)
↓ After above processes are completed, re-install the voltage meter onto the
machine.
Ampere meter (ST-72 by SEW, 0-300A CT ratio: 300/5)
↓Switch off the machine power
↓Detach the ampere meter
↓Connect the ampere meter to AC voltage current stand
(Ex.: Yokogawa 2558 AC voltage current standard)
↓ Switch on the voltage current stand, and check the below current and record the
result
Current Standard (A)
0 (0A)
1 (60A)
1.5 (90A)
2 (120A)
Read value of ampere meter(A)
Deviation
5 (300A)
↓ If there is any deviation between voltage standard and the read value, please
remove the cover and adjust the screw until the read value is correct.
(CAUTION: BE CAREFUL THE HIGH VOLTAGE)
↓ After above processes are completed, re-install the ampere meter onto the
machine.
发布评论